3 Printer Operations
3 Printer Operation
This chapter provides information about printer operation.
3.1 Media Sensor Calibration
You will want the printer to work properly before starting your print jobs. To do this,
you need to calibrate the media sensor. Toshiba B‐FV4T provides transmissive and
reflective sensor calibration. Take the following steps to use them.
1. Make sure the media is properly loaded, the printer module is closed, and the
printer's power switch is set to the OFF position.
2. Press and hold the FEED button, and turn on the printer.
3. Both status lights will light up solid orange for a few seconds. Next, they turn to
green shortly, and then turn to other colors. Do one of the following to select the
sensor:
If you want to calibrate the transmissive sensor, when LED 1 turns to green and
LED 2 turns to red, release the FEED button immediately.
If you want to calibrate the reflective sensor, when LED 1 turns to green and LED
2 turns to orange, release the FEED button immediately.
4. Press the FEED button. The printer will feed 3‐4 labels out and stop.
Toshiba B‐FV4T Owner's Manual
24