Technical Information
4
Service
4.1
Removing the Top Spray Arm
1. Uninstall the appliance.
2. Disconnect the appliance from the power supply.
3. Open the door.
4. Remove the cutlery tray, if applicable.
5. Remove the top basket.
6. Unscrew the screw connection and remove the spray arm.
4.2
Removing the Middle Spray Arm
1. Uninstall the appliance.
2. Disconnect the appliance from the power supply.
3. Open the door.
4. Remove the top basket.
5. Unscrew the screw connection and remove the spray arm.
4.3
Removing the Bottom Spray Arm
1. Uninstall the appliance
2. Disconnect the appliance from the power supply.
3. Open the door.
4. Remove the bottom basket.
5. Remove the spray arm.
4.4
Removing the Top Spray Arm Feed Pipe with Turbidity Sensor
1. Uninstall the appliance.
2. Disconnect the appliance from the power supply.
3. Open the door.
4. Remove the top spray arm; see Section 050-4.1.
5. Unscrew the locknut.
6. Close the door.
7. Remove the right side panel (see Section 010-4.1).
8. Disconnect the turbidity sensor plug connections.
9. Tip the appliance onto its back.
10. Remove the drip pan. See Section 010-4.2.
11. Disconnect the hose clip connection to the circulation pump.
4.5
Removing the Middle Spray Arm Feed Pipe
1. Uninstall the appliance.
2. Disconnect the appliance from the power supply.
3. Open the door.
4. Remove the top basket.
5. Remove the right side panel (see Section 010-4.1).
6. Dismantle the feed pipe on the rear panel inside the cabinet.
94
G 5xxx