Note: The default Gateway must be on the same Subnet as the IP address assigned
in Step 2 (above) for the ATM access module.
4
There is no need to perform a reset.
Configuration Example:
Enter IP Address (149.49.54.249): 149.49.44.80
Enter Netmask (255.255.255.0): 255.255.255.0
Enter Default Gateway (149.49.54.1): 149.49.44.120
Note: If there are any errors, the new configuration settings are not saved. To save
the new configuration settings, you must correct the errors by repeating the
command.

Setting up the ATM Access Module

Once you have assigned an IP address, Netmask and Default Gateway to the ATM
access module you can begin configuring ATM Edge Device parameters such as
LECS, LES and BUS.
You can connect to the ATM access module Terminal Interface either by
disconnecting the console port from the M-SPX/S module and connecting it to the
ATM access module or by establishing a Telnet session to the IP address you
assigned to the ATM access module in the previous section. This is described in
Chapter 4, ATM Access Module Terminal Interface for Configuring ATM
Parameters58.
You can now proceed to configure the ATM access module using CajunView, the
Embedded Web Manager or the CLI interface.
Note: The only way to change the Default Port Speed (from OC-12 to OC-3 or from
OC-3 to OC-12) is via option [4] Port Speed in the ATM Port Menu (see Figure 4.11 on
page 66). The Framing Mode can be either SONET or SDH.
Avaya M770 M-ACCF/SF ATM Access Modules User's Guide