Functional description and configuration using Web Based Management
7.8 The "X200" menu
7.8.3

HSR Coupling Configuration

HSR Coupling Configuration
The HSR-specific parameters are entered in the "Coupling Configuration" dialog box.
Figure 7-18
"Coupling Mode"
Here you can set the coupling mode between HSR and the remaining network.
Coupling Mode
HSR SAN Mode
Non Redundant HSR PRP coupling
Redundant HSR PRP coupling, LAN A
Redundant HSR PRP coupling, LAN B
98
X204 Coupling Configuration
Meaning
The HSR ring is connected with Standard Ethernet end devi‐
ces or network segments (default).
Setting with non-redundant HSR<->PRP coupling. P1/A is
connected with LAN A, P2/B with LAN B of a PRP network.
Setting with redundant HSR<->PRP coupling. P1/A is con‐
nected with LAN A of a PRP network. P2/B is open and may
not be used.
Setting with redundant HSR<->PRP coupling. P1/B is con‐
nected with LAN B of a PRP network. P1/A is open and may
not be used.
Operating Instructions, 10/2016, C79000-G8976-C342-04