Vivax ACP-12CC35AECI Service Manual page 144

Table of Contents

Advertisement

2.4.1.5. Indoor fan speed has been out of control.
Index 1:
1. Indoor DC fan motor(control chip is inside fan motor)
Power on and when the unit is in standby, measure the voltage of pin1-pin3, pin4-pin3 in fan motor
connector. If the value of the voltage is not in the range showing in below table, the PCB must have
problems and need to be replaced.
DC motor voltage input and output
NO.
Color
1
Red
2
---
3
Black
4
White
5
Yellow
6
Blue
Electrical Control System
Signal
Voltage
Vs/Vm
200V~380V
---
---
GND
0V
Vcc
13.5-16.5V
Vsp
0~6.5V
FG
13.5-16.5V
Troubleshooting
141

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents