SystemGuard Maintenance Menu

Starting from the main maintenance menu:
Enter 2 to enable the flag.
OR
Enter 3 to disable the flag.

AIX Diag Command

Starting from the Service Aids Selection menu:
1. Select the BUMP Service Aids option.
2. Select the Display or Change Flags and Configuration option.
3. Select the Change Diagnostic Flags option.
4. Select the Remote Authorization option.
5. Supply a new flag value (0 or 1).

Modifying the Dial-Out Authorization Flag

This flag can be changed under SystemGuard using the maintenance menu, or under AIX
using the diag command.
SystemGuard Maintenance Menu
Starting from the main maintenance menu:
1. Enter 8 to set parameters.
2. Enter 4 for miscellaneous parameters.
3. Enter 2 to change the Dial-Out Authorization flag.

AIX Diag Command

Starting from the Service Aids Selection menu:
1. Select the BUMP Service Aids option.
2. Select the Display or Change Flags and Configuration option.
3. Select the Change Diagnostic Flags option.
4. Select the Dial-Out Authorization option.
5. Supply a new flag value (0 or 1).
B-4
Operator Guide