Specification
Humidity and
Temperature
(continuous operation)
Temperature (storage) -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation
Vibration and shock
OmniCube servers have limits for vibration and shock under operating and storage conditions.
Specification Description
Vibration
(operating)
Vibration
(storage)
Shock
(operating)
Shock
(storage)
Altitude and airborne contaminants
OmniCube servers have limits for altitude and airborne contaminants under operating and storage
conditions.
Specification
Altitude (operating)
Altitude (storage)
Contaminant level (operating)
Agency compliance standards
OmniCube servers meet agency compliance standards.
An OmniCube host complies with the following standards:
•
CNS14436-1, CNS13438
•
UL 60950-1, 2nd Edition, 2011-12-19; CSA C22.2 No. 60950-1-07, 2nd Edition
•
EK1-ITB 2000:2014
•
EMC EMCA41269-EM i EMCA41269-IM od 14.07.2014
Description
10°C to 35°C (50°F to 95°F) at 10% to 80% relative humidity with 26°C
(78.8°F) maximum dew point (maximum wet bulb temperature). De-rate
maximum allowable dry bulb temperature at 1°C per 300m above 950m
(1°F per 547 ft above 3117 ft).
of 20°C per hour.
0.26Grms at 5-350Hz in all orientations.
1.88Grms at 10-500Hz for 15 minutes (all six sides tested).
Six consecutively executed shock pulses in the positive and negative x, y, and z
axes of 40 G for up to 2.3 ms.
Six consecutively executed shock pulses in the positive and negative x, y, and z
axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Description
-15.2m to 3048m (–50 ft to 10,000 ft)
-15.2m to 12,000m (–50 ft to 39,370 ft)
Class G1 or lower as defined by ISA-
S71.04-1985
Environmental and technical specifications
15