5. Digital types operation

(1) Comparison Table of LCD Display Fonts and Actual Fonts
Arabic Numerals:
Actual
Display
(2) Digital Display on the Key Board
English Alphabet
Actual
A
Display
Actual
N
Display
6. User Parameter & Technician Parameter
Parame-
Parameter function
ter code
Maximum sewing
P01
speed (sti/min)
Speed curve adjust-
P02
ment(%)
Needle UP/ DOWN
p03
Start back-tacking
p04
speed (sti/min)
End back-tacking
P05
speed (sti/min)
Bar-tacking speed
P06
(sti/min)
Soft start speed (sti/
P07
min)
Stitch numbers for
P08
soft start(sls)
A u t o m a t i c c o n -
P09
stant-stitch sewing
speed (sti/min)
P10
A u t o m a t i c e n d
back-tacking sew-
ing(can invalidate
the stitch correction
function)
0
1
2
3
4
B
C
D
E
O
P
Q
R
Range/ unit
Default
100 to 4000
3500
1 to100%
80
uP / DN
DN
200 to 3200
1900
200 to 3200
1900
200 to 3200
1900
200 to 1500
800
0 to 99 Stitch-
4
es
200 to 4000
3500
ON / OFF
ON
5
6
7
8
9
F
G
H
I
J
S
T
U
V
W
Key
Maximum speed of machine sewing
The lager the value, the faster to increase
speed
Up: Needle stops at up position
Dn: Needle stops at down position
Start Back-Tacking speed adjustment
End Back-Tacking speed adjustment
Repeat Bar-Tacking speed adjustment
Soft Start speed adjustment
Soft Start stitches setting (one unit = half
stitch)
Constant-Stitch sewing speed [034.SMP] is
set at A(or when one shot signal is active)
The Stitch-Correction is valid in sewing stop.
Note : Valid only when the【0.11.RVM】must
set on B
ON : Invalid (Constant-Stitch sewing, it can
automatic continue action as CD func-
tion)
OFF : Valid (Can't continue execute CD func-
tion)
– 23 –
K
L
M
X
Y
Z
Description