External Device Wiring - Jackson RackStar 44 Installation, Operation And Service Manual

Rackstar series. conveyor dishmachines
Hide thumbs Also See for RackStar 44:
Table of Contents

Advertisement

INSTALLATION
!
CAUTION
Do NOT connect
primary load directly
to Terminal Board!
MAXIMUM LOAD
1 AMP, 240/120 VAC
INPUT L1
(EXTERNAL)
17
Wiring Diagram
Exhaust Fan
Terminal Board
WARNING: DISCONNECT POWER TO MACHINE BEFORE SERVICING
EXHAUST FAN
CONSTANT VOLTAGE
CONNECTION
CONNECTION
LIVE WHEN MACHINE
POWER SWITCH IS ON
OUTPUT TO
FUSE: 3 AMP SLOW-ACTING
EXT. RELAY
L1 OUT
Chemical Supplies
Chemical Dispenser Tube Connection
Points to Rinse Injector:

EXTERNAL DEVICE WIRING

(customer provides)
Dish Machine
Customer Connections
RINSE AID DISPENSER
CONNECTION
LIVE WHEN RINSE
VALVE IS OPEN
FUSE: 3 AMP SLOW-ACTING
L2 OUT
L1 OUT
L2 OUT
P: Pressure Switch (1/4" NPT)
S: Sanitizer (1/8" NPT)
R: Rinse Aid (1/8" NPT)
Contactor
Fuse Block
TIMER
DETERGENT
DISPENSER
CONNECTION
LIVE WHEN WASH
PUMP MOTOR IS ON
FUSE: 3 AMP SLOW-ACTING
L1 OUT
L2 OUT
L1
L2/N
07610-004-33-05-B