Mitsubishi QD75M1 User Manual page 574

Qd75m series. positioning module.
Hide thumbs Also See for QD75M1:
Table of Contents

Advertisement

12 CONTROL SUB FUNCTIONS
Setting item
Positioning
Cd.13
operation speed
override
Refer to section "5.7 List of control data" for details on the setting details.
Positioning start signal
PLC READY signal
All axis servo ON
QD75 READY signal
Start complete signal
BUSY signal
Positioning complete signal
Error detection signal
[2] Precaution during control
(1) When changing the speed during continuous path control, the speed change
will be ignored if there is not enough distance remaining to carry out the
change.
(2) A warning "Deceleration/stop speed change (warning code: 500)" occurs
and the speed cannot be changed in the following cases.
(The value set in "
after a deceleration stop.)
During deceleration by a stop command
During automatic deceleration during positioning control
(3) When the speed is changed during interpolation control, the required speed
is set in the reference axis.
[3] Setting the override function
The following shows the data settings and sequence program example for setting
the override value of axis 1 to "200%".
(1) Set the following data. (Use the start time chart shown in section (2) below
as a reference, and set using the sequence program shown in section (3).)
Setting
value
200
Set the new speed as a percentage (%).
(2) The following shows a time chart for changing the speed using the override
function.
V
[Y10]
[Y0]
[Y1]
[X0]
[X10]
[XC]
[X14]
[X8]
Cd. 13 Positioning operation
speed override
Fig. 12.29 Time chart for changing the speed using the override function
Cd.13
Positioning operation speed override" is validated
Setting details
200
12 - 45
MELSEC-Q
Buffer memory address
Axis
Axis
Axis
Axis
1
2
3
4
1513 1613 1713 1813
Dwell time
t

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd75m2Qd75m4

Table of Contents