Specifications; General Description - Panasonic KX-TDA100 Installation Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

1.4 Specifications

1.4
Specifications
1.4.1

General Description

Control Bus
Communication Bus
Switching
Power Input
External Battery
Maximum Power Failure Tolerance
Memory Backup Duration
Dialling
Mode Conversion
Ring Frequency
Trunk Loop Limit
Operating
Environment
Conference Call Trunk
Music on Hold (MOH)
Paging
Serial Interface Port
26
Installation Manual
Original bus (16 bit, 8 MHz, 10 megabytes per second)
H.100 bus conformity (1024 time slot)
Non Blocking Distributed Time Switch
PSU-S
100 V AC to 130 V AC, 1.4 A/200 V AC to 240 V AC, 0.8 A,
50 Hz/60 Hz
PSU-M
100 V AC to 130 V AC, 2.5 A/200 V AC to 240 V AC, 1.4 A,
50 Hz/60 Hz
PSU-L
100 V AC to 130 V AC, 5.1 A/200 V AC to 240 V AC, 2.55 A,
50 Hz/60 Hz
+36 V DC (+12 V DC × 3, battery capacity of 28 Ah or below
recommended for 1 external battery)
300 ms (without using backup battery)
7 years
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600
Temperature
0 °C to 40 °C
Humidity
10 % to 90 % (non condensing)
From 10 × 3-party conference call to 4 × 8-party conference
call
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Internal
Level Control: -6 dB to +3 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
RS-232C
1 (maximum 115.2 kbps)
USB
1
maximum

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda200