Yamaha SB168-ES Service Manual page 53

Stage box
Hide thumbs Also See for SB168-ES:
Table of Contents

Advertisement

3-3.
FAN test
Contents
Checks the fan operation.
Screen Example
Output result
• Normal condition
Displays in the output window as follows.
Item
Text indication
Fan Normal
OK: Fan Normal
• In case of failure
Displays in the output window as follows.
Item
Text indication
Fan Normal
NG: Fan Normal
3-4.
PLLP2 test
Contents
Checks PLLP2 register by reading/writing it.
Screen Example
Output result
• Normal condition
Displays in the output window as follows.
Item
Text indication
Address Data Bus
OK: PLLP2
• In case of failure
Displays in the output window as follows.
Item
Text indication
NG: PLLP2 REG:0x00 W:xxxxh R:xxxxh
NG: PLLP2 REG:0x0F W:xxxxh R:xxxxh
Address Data Bus
NG: PLLP2 REG:0x10 W:xxxxh R:xxxxh
NG: PLLP2 REG:0x16 W:xxxxh R:xxxxh
* The "W: xxxxh" in text indication shows a write data in
hexadecimal notation.
* The "R: xxxxh" in text indication shows a read data in
hexadecimal notation.
SB168-ES