Phone Patch And Tone Remote - Icom IC-FR5100 Series Handbook

Vhf and uhf fm repeaters
Table of Contents

Advertisement

Basic Repeater to Phone Line Connecting System
Antenna
Combine
r
Public Telephone line
This is an example for a telephone connection added
to a single repeater site. The IC-FR5100/6100
repeater can be connected to the telephone line via
an external phone patch device. When a subscriber
transmits DTMF dialing codes, the received signal is
sent to the telephone line to connect the phone.
Repeater and Worldpatch connection
Repeater (25pin)
Pin Description
Pin No.
11
<>
+13.6V OUT
9
<>
DISC OUT
8
<>
MOD IN
19
<>
EPPT
15
<>
Busy
7,14
<> 2, 4, 6
GND
System requirements with Telephone connection (One
site)
Descriptions
UHF Repeater
UHF Antenna
Antenna Combiner
ZETRON Worldpatch
Note: The above connections are for your reference only..
5-4

Phone Patch and Tone Remote

IC-FR6100
ZETRON
Worldpatch
Telephone line
Worldpatch (10pin)
Pin No.
Pin Description
1
+12V IN
3
DISC IN
5
TX AUD
7
PTT OUT
8
COR IN
GND
Model Number
Quantity
IC-FR6100
Tone Remote System
Antenna
Combiner
Tone Remote
This is an example for a Tone Remote Controller
added to a single repeater site.
Repeater and Tone Remote Adapter
connection
Repeater (25pin)
Pin Description
Pin No.
11
+13.6V OUT
22
AF OUT
8
MOD IN
19
EPPT
17*
Key Moni
7,14
GND
MCH Select :1
15*
16*
MCH Select :2
23*
MCH Select :3
24*
MCH Select :4
25*
MCH Select :5
* The desired functions can be assigned to EXT. I/O
15 to 25.
System requirements (One site)
Descriptions
Repeater
Antenna
Antenna Combiner
Tone Remote Adapter
Tone Remote
IC-FR6100
Tone Remote
Adapter
Tone Remote Adapter
Pin No.
Pin Description
<>
+12V IN
<>
RX IN
<>
TX OUT
<>
PTT OUT
<>
MONITOR OUT
<>
GND
<>
F1
<>
F2
<>
F3
<>
F4
<>
F5
Model Number
Quantity
IC-FR6100
44

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic-fr6100 series

Table of Contents