Comtech EF Data C Installation And Operation Manual page 45

Hpod high-powered outdoor amplifier
Table of Contents

Advertisement

HPOD
Customer Commands
Command
(Instruction
Parameter Type
Code and
Qualifier)
Retrieve Utility
N/A
Status
RF Power
AMP=
Amplifier State
RF Power FET
N/A
Current status
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric
Response to
codes, that is, ASCII codes between 48 and 57)
Query
27 bytes,
Query only.
alpha- numeric
Used to Query the utility status of the unit
Example: RUS='cr'
ADR=0001'cr'
BDR=9600'cr'
1 byte,
Command or Query
value of 0, 1
Turns ON or OFF the RF power amplifiers.
0 = Off
1 = On
Example: AMP=1'cr'
variable length
Query only
depending on
Used to display all the FET currents.
the number of
FETs installed in
Example: <1/RFS? 'cr'
the amplifier
>0001/RFS='cr'
Q01=xx'cr'
Q02=xx'cr'
Q03=xx.x'cr'
Q04=xx.x'cr'
Q05=xx.x'cr'
Q06=xx.x'cr'
Q07=xx.x'cr'
Q08=xx.x'cr'
Q09=xx.x'cr'
Q10=xx.x'cr'
Q11=xx.x'cr'
Q12=xx.x'cr'
Q13=xx.x'cr'
Q14=xx.x'cr'
Q15=xx.x'cr'
Q16=xx.x'cr''lf'
Response to
Command
(Target to controller)
AMP= (message ok)
AMP? (received ok, but
invalid arguments
found)
AMP* (message ok, but
not permitted in current
mode)
4–19
Revision 1
MN/HPOD.IOM
Query
(Instruction
Code and
qualifier)
N/A
RUS?
AMP?
N/A
RFS?
Response to
query
(Target to
controller)
RUS=x....x
(see description
for details of
arguments)
AMP=x
(same format as
command
arguments)
RFS=x....x
(see description
of arguments)

Advertisement