Comtech EF Data C Installation And Operation Manual page 43

Hpod high-powered outdoor amplifier
Table of Contents

Advertisement

HPOD
Customer Commands
Command
(Instruction
Parameter Type
Code and
Qualifier)
Retrieve
N/A
Maintenance
Status
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric
Response to
codes, that is, ASCII codes between 48 and 57)
Query
168 bytes,
Query only.
alpha- numeric
Used to Query the maintenance status of the unit
Example:<1/RMS?'cr'
>0001/RMS='cr'
P24VT=024.1'cr'
P15VT=015.2'cr'
P10V1=010.4'cr'
P10V2=010.4'cr'
P7V5T=007.8'cr'
P5VLT=005.8'cr'
N5VLT=-05.7'cr'
FANR1=100.0'cr'
FANR2=100.0'cr'
ATEMP=+40.0'cr'
A10V1=010.2'cr'
A10V2=010.2'cr'
FWPWR=+37.6'cr'
RVPWR=02.0'cr''If' (optional)
*Note: REFV will appear if REF OSC module is
installed.
Response to
Command
(Target to controller)
N/A
4–17
Revision 1
MN/HPOD.IOM
Query
Response to
(Instruction
query
Code and
(Target to
qualifier)
controller)
RMS?
RMS=x....x
(see description
for details of
arguments)