Comtech EF Data C Installation And Operation Manual page 36

Hpod high-powered outdoor amplifier
Table of Contents

Advertisement

HPOD
Customer Commands
Command
(Instruction
Parameter Type
Code and
Qualifier)
Circuit
CID=
Identification
Clear All Stored
CAA=
Alarms
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric
Response to
codes, that is, ASCII codes between 48 and 57)
Query
24 bytes,
Command or Query
alpha-numeric
CID is a user-defined string of data that may be
used to identify or name the unit or station. The
CID is a 24-byte field of data that is entered as one
line, but it will be read back from the unit as two
12-byte lines of data.
Examples:
<1/CID= Station #001--HPOD #01--'cr'
>0001/CID=
<1/CID?'cr'
>0001/CID='cr'
Station #001'cr'
--HPOD #01--'cr''lf'
None
Command only
Instructs the slave to clear all Stored Events
This command takes no arguments.
Example: <1/CAA='cr'
>0001/CAA='cr''lf'
Response to
Command
(Target to controller)
CID= (message ok)
CID? (received ok, but
invalid arguments
found)
CAA= (message ok)
4–10
Revision 1
MN/HPOD.IOM
Query
Response to
(Instruction
query
Code and
(Target to
qualifier)
controller)
CID?
CID=x...x
(see description
for details of
arguments)
N/A