HPOD
Customer Commands
Command
(Instruction
Parameter Type
Code and
Qualifier)
Concise Alarm
N/A
Status
Concise
N/A
Configuration
Status
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric
Response to
codes, that is, ASCII codes between 48 and 57)
Query
25 bytes,
Query only.
alpha-numeric
Used to Query the Alarm status of the unit,
response is comma delimited.
Example: CMS=a,b,c,d,e,f,g,h,I,j,k,I,m'cr''lf'
where: a thru k = 0 or 1, 0 = OK 1 = FT
a = +24V Power Supply
b = +15V Power Supply
c = +10V-A Power Supply
d = +10V-B Power Supply
e = +7.5V Power Supply
f = +5V Power Supply
g = -5V Power Supply
h = Fan#1 State
i = Fan#2 State
j = Heatsink Temp
k = Shutdown
l = llC Status
m=Forward Power Alarm
24 bytes,
Query only.
alpha-numeric
Used to query the summarized version of RCS.
Example: CCS=aaaaa,b,c,d,e-e,fffff,g,'cr'
Where:
aaaaa = attenuation in dB
b = RF power amplifier state
c = mute state, 0 = un-muted, 1 = muted
d = online status
e-e = redundancy state and mode
fffff = gain offset in dB
g = AFR
Response to
Command
(Target to controller)
4–11
Revision 1
MN/HPOD.IOM
Query
(Instruction
Code and
qualifier)
N/A
CAS?
N/A
CCS?
Response to
query
(Target to
controller)
CAS=x....x
(see description
for details of
arguments)
CCS=x....x
(see description
for details of
arguments)