DS6R2 | Installation and Operation Guide | 1.0 Overview

1.0 Overview

1.1

Multi-Tenant System (MTS) Overview

MTS is a distributed security system for monitoring
and controlling a large number of small sites.
Examples include apartment and condominium
complexes, retail plazas, office buildings, and
educational and hospital campuses.
A typical MTS installation consists of the following
components:
MTSW Security Station Software: MTSW is a
®
Microsoft
Windows-based application installed on
a PC and monitored by guard station personnel.
MTR Communication Receiver: The MTR
receives and handles alarm events from devices
connected to the CAN RS-485 bus. It monitors
and reports CAN bus status and other system
internal events, and interfaces with MTSW to
synchronize system data.
MTGW CAN RS-485 Bus Gateway: The MTGW
converts data back and forth from an RS-485
format to a Controller Area Network (CAN) bus
format. The system supports up to 100 MTGWs
per CAN bus line. The MTGW provides three RS-
485 loops that support a total of 120 RS-485
devices spread across the three loops.
RS-485 Bus Devices: Refer to Table 1 for a list of
supported RS-485 devices.
Table 1: MTS RS-485 Bus Devices
RS-485 Device
Description
DS6R2
6-zone self-contained control panel
DS12R
12-zone self-contained control panel
MT1-1
Single-zone input device
MT1-2
Two-zone input device
MT1-8
8-zone input device
MT2-8
8-output device
MT3-1
Single-zone input/output device
4
CAN bus wiring requirements are as follows:
CAN Bus Interface: Connect the CAN bus to the
MTR Communication Receiver with at least
1.5 mm (16 AWG) shielded twisted-pair wire;
maximum length: 2000 m (6500 ft).
RS-485 Buses 1-3: Use at least 1.0 mm (20 AWG)
shielded twisted-pair wire for the RS-485 bus;
maximum length: 1200 m (3900 ft). RS-485 bus
wiring status is supervised.
1.2

MTS Device Address

You must assign an address to each device in the
system. The address consists of at least four segments.
For example:
1.2.5.3.6
1: This segment identifies the number assigned to
the MTR central receiver (01 to 99).
2: This segment identifies the CAN bus number
occupied by the MTGW (1 or 2).
5 : This segment identifies the MTGW's CAN bus
address (1 to 100).
3 : This segment identifies the device's RS-485
address (1 to 120).
6 : This segment identifies the zone number of an
input or output device connected to the RS-485
device.
To set the address on this device, refer to Section 6.0
RS-485 Bus Address on page 16.
1.3

DS6R2 Overview

The DS6R2 is a self-contained, six-zone control panel.
Use it as a stand-alone security system, or connect it to
a Multi-tenant System (MTS). MTS combines
individual apartment housing units into a single
monitoring system.
The DS6R2 supports:
6 alarm input zones
1 alarm relay output
2 solid-state outputs
1 keyswitch input
1 master code
3 user PIN codes
1 duress code
1 door unlock code
RF3212 and RF3212E Wireless Receiver
RF3332 and RF3334 Key Fobs
RF3332E and RF3334E Key Fobs