Electrical Data - Outdoor Unit - Ac With Powered Convenience Outlet - York R-410A Technical Manual

Split-system air-cooled condensing units and air handlers
Hide thumbs Also See for R-410A:
Table of Contents

Advertisement

505428-YTG-V-0417

Electrical Data - Outdoor Unit - AC With Powered Convenience Outlet

Compressors
Model
Power
Qty
Supply
208/230-3-60
1
YC090
460-3-60
1
575-3-60
1
208/230-3-60
2
YC120
460-3-60
2
575-3-60
2
208/230-3-60
2
YD120
460-3-60
2
575-3-60
2
208/230-3-60
2
YC150
460-3-60
2
575-3-60
2
208/230-3-60
2
YD150
460-3-60
2
575-3-60
2
208/230-3-60
2
YC180
460-3-60
2
575-3-60
2
208/230-3-60
2
YD180
460-3-60
2
575-3-60
2
208/230-3-60
2
YC240
460-3-60
2
575-3-60
2
208/230-3-60
2
YD240
460-3-60
2
575-3-60
2
208/230-3-60
2
YC300
460-3-60
2
575-3-60
2
1
Based on three, 75°C insulated copper conductors in conduit and ambient of 30°C.
2
Maximum fuse or maximum circuit breaker (HACR type per NEC).
Refer to NEC/NFPA No. 70, Articles 440-11, 12 for information on minimum disconnect sizing.
64
RLA
MCC
LRA
(each)
(each)
(each)
25.0
39
164
208/230-1-60
12.2
19
100
460-1-60
9.0
14
78
575-1-60
15.7
24.5
110
208/230-1-60
7.8
12.0
52
460-1-60
5.8
9.1
39
575-1-60
16.0
25
110
208/230-1-60
7.8
12
52
460-1-60
5.7
9
39
575-1-60
22.4
35
149
208/230-1-60
10.6
17
75
460-1-60
7.7
12
54
575-1-60
22.4
35
149
208/230-1-60
10.6
17
75
460-1-60
7.7
12
54
575-1-60
25.0
39
164
208/230-1-60
12.2
19
100
460-1-60
9.0
14
78
575-1-60
25.0
39
164
208/230-1-60
12.2
19
100
460-1-60
9.0
14
78
575-1-60
30.1
47
225
208/230-1-60
16.7
26
114
460-1-60
12.2
19
80
575-1-60
30.1
47
225
208/230-1-60
16.7
26
114
460-1-60
12.2
19
80
575-1-60
48.1
75
245
208/230-1-60
18.6
29
125
460-1-60
14.7
23
100
575-1-60
Outdoor Fan Motor
Power
FLA
HP
Qty
Supply
(each)
1/3
2
2.1
1/3
2
1.2
1/3
2
0.9
3/4
2
3.0
3/4
2
1.6
3/4
2
1.4
3/4
2
3.0
3/4
2
1.6
3/4
2
1.4
3/4
2
3.0
3/4
2
1.6
3/4
2
1.4
3/4
2
3.0
3/4
2
1.6
3/4
2
1.4
1/3
4
2.1
1/3
4
1.2
1/3
4
0.9
3/4
4
3.0
3/4
4
1.6
3/4
4
1.4
3/4
4
3.0
3/4
4
1.6
3/4
4
1.4
3/4
4
3.0
3/4
4
1.6
3/4
4
1.4
3/4
4
3.0
3/4
4
1.6
3/4
4
1.4
Pwr Conv Outlet
Minimum
Circuit
FLA
Ampacity
10.0
45.5
5.0
22.6
4.0
17.1
10.0
51.4
5.0
25.8
4.0
19.8
10.0
52.1
5.0
25.8
4.0
19.5
10.0
66.5
5.0
32.1
4.0
24.0
10.0
66.5
5.0
32.1
4.0
24.0
10.0
74.7
5.0
37.2
4.0
28.0
10.0
78.4
5.0
38.9
4.0
29.7
10.0
89.8
5.0
49.0
4.0
36.9
10.0
89.8
5.0
49.0
4.0
36.9
10.0
130.3
5.0
53.3
4.0
42.5
Johnson Controls Unitary Products
Maximum
Fuse Size
1
2
(A)
60
30
25
60
30
25
60
30
25
80
40
30
80
40
30
90
45
35
100
50
35
110
60
45
110
60
45
175
70
50