Connection To Power Source - Fujitsu IP-920 E/DC Hardware User's Manual

Table of Contents

Advertisement

2.2.2

Connection to power source

IP-920E/DC is safety-approved Class III devices of IEC60950-1, UL60950-1 and EN60950-1.
Therefore, IP-920E/DC needs power source from SELV. Also, in case of using this device in the
United States, it needs to be a UL60950-1 approved power-supply unit.
Prepare a power-supply unit outputting DC12-24V with a power consumption of more than 40W
and connect to this equipment by using the attached DC power cable.
* In case of using non-attached power cable, select a power cable referring to (9) in "4.2 Cable
Connector Details."
Also, power cable can be ordered separately with your suitable length.
<Reference>
・DC power cable (3m)
・DC power cable (length specification) : TA77057-xxxx (Maximum length : 3m)
DC power output equipment
(SELV safety status)
: TA77057-3000 (normally attached)
(TA77057-0500 is 0.5m, TA77057-2000 is 2m)
Power connector
12 - 24V
PWR ALM
RDY
FG
To connect a cable, insert it until
it clicks into place.
To remove a cable, unplug it
while holding down the button.
PUSH
Figure Power cord connection