Specifications

Service Flow Rate (Maximum) .............................................
Rated Service Life OWF-51-NI300 (Maximum) ....................
Rated Service Life OWF-51-WI500 (Maximum) ....................
Maximum Operating Temperature ........................................
Minimum Pressure Requirement ..........................................
Minimum Operating Temperature .........................................
Maximum Operating Pressure ..............................................
General Use Conditions:
DO NOT use this product where water is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system. System certified for cyst reduction may be used on disinfected water that may contain
filterable cysts.
This systems has been tested according to ANSI/NSF 42 and 53 for reduction of the substances listed
below. The concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system, as specified in
ANSI/NSF 42 and 53.
3HUIRUPDQFH 'DWD
Influent challenge
Substance
concentration
Lead
0.15 mg/L +/- 10%
Lead
0.15 mg/L +/- 10%
Cyst
Minimum 50,000/L
Turbidity
11 +/- 1 NTU
Lindane
0.002 mg/L +/- 10%
Atrazine
0.009 mg/L +/- 10%
Chlorine
2.0 mg/L +/- 10%
at least 10,000
Particulate**
particles/mL
2,4-D
0.210 mg/L +/- 10%
107 to 108 fi b ers/L; fi b ers greater than
Asbestos
10 mi c ometers i n l e ngth
Tested using a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa)
under standard laboratory conditions, however, actual performance may vary. Health Claim
Performance tested and certified by NSF International
**
Particle size range classification of test. Particles used were 0.5 –1 microns.
Pentapure, Incorporated
System Specification and Performance Data Sheet
Refrigerator Water Filter Cartridge Model OWF-51
Average
Effluent
%
Average
Reduction
0.001 mg/L
99.33%
0.002 mg/L
98.66%
1count/mL
99.99%
0.12 NTU
98.98%
0.00005 mg/L
92.06%
0.0002 mg/L
97.93%
0.09 mg/L
95.26%
900 count/mL
99.68%
45.45 ug/L
84.42%
0.16 MFL/mL
99.96%
Š

Water Filter Data

Maximum
Min. Required
Effluent
Reduction
0.001 mg/L
0.010 mg/L
0.003 mg/L
0.010 mg/L
3 count/mL
> 99.95%
0.18 NTU
0.5 NTU
0.00005 mg/L 0.00001 mg/L
0.0006 mg/L
0.003 mg/L
75%
0.17 mg/L
85%
2400 count/mL
100 ug/L
0.0017 mg/L
0.16 MFL/mL
99%
Tested and Certified by NSF International against ANSI/NSF Standards
42 & 53 in models OWF51-W1500 and OWF51-N1300 for the reduction of:
Standard No. 42: Authentic Effects
Taste & Odor Reduction
Chlorine Reduction Class 1
Mechanical Filtration Unit
Particlate Reduction Class 1
A-26
Inlet
pH
6.5
8.5
NA
NA
NA
NA
NA
NA
NA
NA
Standard No. 53: Health Effects