Water filter data

Specifications
Service Flow Rate (maximum) ...............................................0.75 GPM (2.83 L/min)
Rated Service Life WF50-NI300 (maximum) .........................300 gallons/1135 liters
Rated Service Life WF50-WI500 (maximum) ........................500 gallons/1892 liters
Maximum Operating Temperature..........................................100° F/38° C
Minimum Operating Temperature...........................................33° F/1° C
Minimum Pressure Requirement............................................35 psi/138 kPa
Maximum Operating Pressure ...............................................120 psi/827 kPa

PERFORMANCE DATA

Influent Challenge
Substance
Concentration
Lead
0.15 mg/L +/- 10%
Lead
0.15 mg/L +/- 10%
Cyst
Minimum 50,000/L
Turbidity
11+/-1 NTU
Lindane
0.002 mg/L +/- 10%
Atrazine
0.009 mg/L +/- 10%
Chlorine
2.0 mg/L +/- 10%
Particulate**
at least 10,000
particles/mL
2,4-D
0.210 mg/L +/- 10%
Asbestos
10
to 10
fibers/L; fibers greater
7
8
than 10 micometers in length
* Tested using a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa) under
standard laboratory conditions, however, actual performance may vary. Health Claim Performance test-
ed and certified by NSF International
** Particle size range classification of test. Particles used were 0.5 –1 microns.
1000 Apollo Road
Eagan, Minnesota U.S.A.
EPA EST #35917-MN-1
20
SYSTEM SPECIFICATION AND
PERFORMANCE DATA SHEET
REFRIGERATOR WATER FILTER
CARTRIDGE MODEL WF50
Effluent
Average %
Average
Reduction
0.001 mg/L
99.33%
0.002 mg/L
98.66%
1count/mL
99.99%
0.12 NTU
98.98%
0.00005 mg/L
97.62%
0.0002 mg/L
97.93%
0.09 mg/L
95.26%
900 count/mL
99.68%
45.45 ug/L
84.42%
0.16 MFL/mL
99.96%
Maximum
Min. Required Inlet
Effluent
Reduction
pH
0.001 mg/L
0.010 mg/L
6.5
0.003 mg/L
0.010 mg/L
8.5
3 count/mL
> 99.95%
NA
0.18 NTU
0.5 NTU
NA
0.00005 mg/L
0.00002 mg/L
NA
0.0006 mg/L
0.003 mg/L
NA
0.17 mg/L
≥75%
NA
2400 count/mL
≥85%
NA
100 ug/L
0.0017 mg/L
NA
0.16 MFL/mL
99%
NA
Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in
models WF50-WI300 and WF50-NI500 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction Class 1

GENERAL USE

CONDITIONS
Read this Performance Data Sheet and
compare the capabilities of this unit with
your actual water treatment needs.
DO NOT use this product where water
is microbiologically unsafe or of
unknown quality without adequate
disinfection before or after the
system. System certified for cyst
reduction may be used on disinfected
water that may contain filterable cysts.
Use only with cold water supply.
Check for compliance with the state
and local laws and regulations.
The Amana
Clean 'n Clear™ retractable
®
water filtration system uses a WF50
replacement cartridge. Timely replace-
ment of filter cartridge is essential for
performance satisfaction from this filtra-
tion system. Please refer to the applica-
ble section in this owner's manual for
general operation, maintenance require-
ments and troubleshooting.
This system has been tested according to
ANSI/NSF 42 and 53 for reduction of the
substances listed below. The concentra-
tion of the indicated substances in water
entering the system was reduced to a
concentration less than or equal to the
permissible limit for water leaving the sys-
tem, as specified in ANSI/NSF 42 and 53.
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane and 2, 4-D Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents