System Maintenance Switch - HP ProLiant ML110 G7 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML110 G7:
Table of Contents

Advertisement

Install the DIMM.
6.
Install the access panel
7.
Lock the tower bezel.
8.
Connect each power cord to the server.
9.
Connect each power cord to the power source.
10.
Power up the server.
11.

System maintenance switch

Position
1
2
3
4
5
6
7
8
9
10
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all
system configuration settings from both CMOS and NVRAM.
CAUTION:
properly configure the server or data loss could occur.
("Installing the access
Default
Function
Off
Off = iLO 3 security is enabled
On = iLO 3 security is disabled
Off
Off = System configuration can be
changed
On = System configuration is locked
Reserved
Reserved
Off
Off = Power-on password is enabled
On = Power-on password is disabled
Off
Off = No function
On = Clear NVRAM
Reserved
Reserved
Reserved
Reserved
Clearing CMOS and/or NVRAM deletes configuration information. Be sure to
panel" on page 24).
Removal and replacement procedures 63

Advertisement

Table of Contents
loading