Electrical Connection - CDA HN7242FR Installation, Use And Maintenance Manual

Table of Contents

Advertisement

ELECTRICAL CONNECTION

 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician who operates in conformance with the normative
regulations.
 Protection against the parts under tension must be ensured after installation.
 The rating plate for this appliance is on the hob casing near the connection box.
 The connection to the mains must be made using a fixed fused spur with a contact distance
of at least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses and/or isolators.
 The isolation switch/fused spur must be accessible in accordance with the installation
regulations.
 The mains cable must be positioned so that it does not touch any of the hot parts of the
hob or even.
Caution!
This appliance must only be connected to a network 230 V~ 50/60 Hz.
Always connect the earth wire.
Respect the connection diagram.
The green / yellow wire corresponds to the earth wire, the blue wire corresponds to the neutral
wire and the brown wire corresponds to the live/phase.
Mains
230V~ 50Hz
400V~ 50Hz
* calculated with the simultaneous factor following standard TN 60 335-2-6
Connection of the hob
Setting up the configuration:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
st
Put the 1
bridge between terminal 1 and 2, the 2
Attach the earth to the terminal "earth", the neutral N to terminal 3 or 4, the Phase L either
terminals 1 or 2.
Biphase
400V~2P+N
Put a bridge between terminal 3 and 4.
Attach the earth to the terminal "earth", the neutral N to terminal 3 or 4, the Phase L1 to terminal
1 and the Phase L2 to terminal 2.
Caution!
Ensure that the cables are correctly inserted and screwed down tightly.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
Connection
Cable diameter
1 Phase + N
3 x 2,5 mm
2 Phases + N
4 x 1.5 mm²
Cable
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
H 05 RR - F
nd
between 3 and 4.
18
Protection calibre
25 A *
16 A *

Advertisement

Table of Contents
loading