Must be Super HP Revs P100.13 or Greater, X-Mega Revs 101.02 or Greater
STEP 1S
STEP 2S
FILTERING
TYPE
SET
STEP 3S
RELAY 1 "GALLONS"
TRIGGER
SET
RELAY 1 SETPOINT
500
GAL
SET
RELAY 1 DURATION
10:00
SET
RELAY 2 "TIME"
TRIGGER
SET
RELAY 2 SETPOINT
0
SET
MIN
RELAY 2 DURATION
10:00
SET
9
Demand Aeration Programming
FILTER SETUP
=  Up Arrow
STEP 1S – Press NEXT and  simultaneously for 3 seconds. If screen in Step 2S does not
appear in 5 seconds the lock on the valve is activated.
STEP 2S – Select between softening or filtering. A flashing "SOFTENING" or
"FILTERING" will appear. Choose FILTERING using  or  button. Factory setting is Filter-
Press NEXT to step through filter programming to relay programming displayed
ing.
on Step 3S.
Press REGEN to exit Filter System Setup.
STEP 3S – Set Relay 1 Trigger. Gallons chosen to activate relay. If Off or Time was selected
in previous steps, this screen does not appear use
gallons. Press NEXT to got to step 4S. Meter does not read during regeneration.
STEP 4S – Use up and down arrows to select number of gallons per relay activation
STEP 4S
of regen gallon setting. Range = 0.1-20,000 gallons. Press NEXT to go to Step 5S.
STEP 5S – Use up and down arrows to set duration of relay activation in minutes.
STEP 5S
Range = 1 second - 500 minutes. Recommended duration is 10:00 minutes. Press
MIN
NEXT to go to Step 6S. Press REGEN to return to previous step.
STEP 6S – Set Relay 2 Trigger. Use
STEP 6S
time. Press NEXT to got to step 7S. Meter does not read during regeneration.
STEP 7S – Use up and down arrows to select number of minutes after start of regen-
STEP 7S
eration that relay closes and initiates air recharge cycle. Range = 20 - 500 minutes.
Press NEXT to go to Step 8S.
STEP 8S – Use up and down arrows to set duration of relay activation in minutes.
STEP 8S
Range = 1 second - 500 minutes. Recommended duration is 10:00 minutes.
MIN
Press REGEN to return to previous step. Press NEXT to program service alarm if
desired.
=  Down Arrow
or  down arrows to set relay trigger to
or  down arrows to set relay 2 trigger to