RECLAIM
STEP 8CS
ENABLED
SET
MAV RECLAIM START
10:00
SET
RECLAIM DURATION
15:00
SET
MAV RECLAIM 2 START
26:00
SET
RECLAIM 2 DURATION
10:00
SET
SYSTEM BOARD
STEP 9CS
ENABLED
SET
AUX MAV OFF
STEP 10CS
TRIGGER
SET
AUX MAV RECLAIM
STEP 11CS
TRIGGER
SET
AUX RECLAIM START
30:00
SET
12
STEP 8CS – Configuring the Control Valve for Water Reclamation Mode - Select Reclamation
Enabled for control operation. Motorized Alternating Valve will advance to Bypass at a set time
after the beginning of regeneration, and return to Service after a set duration.
The start of regeneration is defined as the first cycle that is not FILL or FILTERING. The Alter-
nating MAV will transition back to Service after the completion of the preset duration time, labeled
Reclaim Duration. Three reclaim events are possible. Select either Reclaim Enabled, Reclaimed
2x for two events and Reclaim 3X for three separate reclaim events.
Use the  or  to select minutes after start of regeneration to activate MAV to reclaim
position for 1st reclaim event. Press NEXT to set duration of reclaim
MIN
Use the  or  buttons to select minutes of 1st reclaim duration. Press NEXT to go to
next reclaim event if more than one event is selected. Press NEXT to go to Step 10CS
MIN
If only one reclaim event is selected.
Only displays if more than one reclaim event is selected. Use  or  buttons to select
number of minutes after start of regeneration for second reclaim event.
MIN
Press NEXT to program second reclaim duration. Use  or  buttons to set length of
second duration.
MIN
Press NEXT to program third reclaim event or to Step 10CS.
STEP 9CS – Configuring the Control Valve to operate with the Hellenbrand System Con-
troller - Select System Board Enabled to link the Control Valve to the SystemMate Controller.
For communication between the Control Valve and the System Controller, a three wire communi-
cation cable is required.
Press NEXT to go to Step 10CS. Press REGEN to return to previous step.
STEP 10CS – Use the  or  buttons to select one of the following:
• Reclaim – Allows water or regenerant reclaimation. Up to 3 reclaim events can be
programmed – See instructions below.
• Separate Source –Allows Auxiliary MAV to switch positions before the start of regeneration
and to switch back at the end of regeneration. See instructions in Step 14CS.
• Off - Factory Setting is Off
Press NEXT to go to Step 11CS when reclaim selected as trigger. Press REGEN to return to
previous step.
STEP 11CS – Use the  or  buttons to select reclaim as Aux MAV Trigger. This option is
usually done with softeners for brine reclaim but can be used to reclaim water used during
regeneration. Three reclaim events are possible. RECLAIM is one event. RECLAIM 2X is two
events and RECLAIM 3X is selected for 3 different reclaim events.
STEP 12CS – Only displays if reclamation of brine is enabled in Step 11CS. Use the 
STEP 12CS
or  buttons to select the number of minutes after the start of regeneration before the
MIN
MAV will divert the waste water from the plumbing drain receptacle to the storage tank.
Start of regeneration is defined as any mode that is not fill or softening.
Press NEXT to go to Step 13CS. Press REGEN to return to previous step.