Hellenbrand Iron Curtain 2.0 Owner's Manual page 13

Demand aeration
Hide thumbs Also See for Iron Curtain 2.0:
Table of Contents

Advertisement

AUX RECLAIM DURATION
6:00
SET
MAV RECLAIM 2 START
38:00
SET
RECLAIM 2 DURATION
15:00
SET
AUX MAV SEP SOURCE
STEP 14CS
TRIGGER
SET
AUXILIARY INPUT
STEP 15CS
ON 0
REG
SET
FILTERING
STEP 16CS
CYCLE 1
SET
BACKWASH
STEP 17CS
CYCLE 4
SET
RINSE
STEP 18CS
CYCLE 6
SET
ALT FILL TRIGGER
STEP 19CS
REGENS
OFF
SET
ALT FILL AMOUNT
STEP 20CS
15.0
LBS
SET
13
STEP 13CS – Only displays if reclamation is enabled in Step 11CS. Use the  or 
STEP 13CS
buttons to select the number of minutes to divert the waste water to the storage tank.
MIN
After the minutes count down to zero the waste water will once again be diverted to
the plumbing drain receptacle. Press NEXT to program next reclamation event if
more than one selected. Press NEXT to go to Step 15CS if only one reclaim event
desired. Press REGEN to return to previous step.
Only displays if RECLAIM 2X is selected. Use  or  buttons to select number of
MIN
minutes after start of regeneration for Aux MAV to divert waste water. Press NEXT
to program number of minutes for duration of second reclaim event. Use the  or
 buttons to select number of minutes of duration of second reclaim event. Press
NEXT to program next reclaim event or go to Step 15 CS if no further reclaim re-
quired.
MIN
STEP 14CS – Separate source selection requires connection of motorized alternator valve
(MAV) to Auxiliary Drive two-pin connection on board. Auxiliary MAV Drive set to operate with a
Separate Source trigger. Auxiliary MAV transitions to Bypass before the start of regen cycle #1,
AFTER Alternator MAV motor transition. Auxiliary MAV transitions back to Service at the comple-
tion of the last programmed regen cycle, once the Valve Motor deactivates and BEFORE Alterna-
tor MAV transition (if scheduled). Auxiliary MAV will NOT automatically return to Service while
manually stepping valve through regen, MAV will remain in Bypass until regen cycle end. Press
NEXT to go to Step 15CS. Press REGEN to return to previous step.
STEP 15CS – This display will be available to select the use of an outside signal to control the
initiation of a regeneration. Selection only matters if a connection is made to the two pin connec-
tor labeled DP SWITCH located on the printed circuit board. Following is an explanation of the
options:
• IMMED – If the dP switch is closed for an accumulative time of 2 minutes, a regeneration will
occur immediately.
• DELAY REGEN – If the dP switch is closed for an accumulative time of 2 minutes, a regenera-
tion will occur at the schedule regeneration time.
• HOLD REGEN – If the dP switch is closed a regeneration will be prevented from occurring.
• OFF - Factory setting is off
Press NEXT to go to Step 16CS. Press REGEN to return to previous step.
STEP 16CS – Press the  or  buttons until selection of first cycle appears in left upper corner,
in this example FILTERING is selected. Press NEXT to go to Step 17CS. Press REGEN to return
to previous step.
STEP 17CS – Press the  or  buttons until selection of fourth cycle appears in left upper cor-
ner, in this example BACKWASH is selected. Press NEXT to go to Step 18CS. Press REGEN to
return to previous step.
STEP 18CS – Press the  or  button until selection of third regeneration cycle appears (up to 9
regeneration modes are possible). End must be selected as last cycle. Press NEXT to go to
Step 19CS.
STEP 19CS – Press the  or  button to select number of standard regenerations which would
trigger one alternate regenerant fill amount. Brine elbow must be installed for this to function.
Range: 1-99. Factory setting is Off. Press NEXT to go to Step 20CS.
STEP 20CS – Select amount of regenerant to be used when alternate regeneration requested.
Brine elbow usually contains 0.5 gpm flow control button. This screen is not displayed if off is
selected in previous step. Softener Range 0.1–200 lbs. Software assumes 0.5 gpm flow control
is in place to determine length of fill time. Filter Range 0.05–20.0 Gallons.