Siemens SITRANS F M MAG 8000 Operating Manual page 22

Battery operated water meter
Hide thumbs Also See for SITRANS F M MAG 8000:
Table of Contents

Advertisement

MAG 8000 & MAG 8000 CT
FT/PDM Meter
Display Parameter/data type
number
version view
104
All
O5
105
All
-
106
All
-
107
All
-
108
All
-
120
All
-
130
All
-
131
All
-
200
All
O4
201
All
-
202
All
-
203
All
O4
204
All
-
205
All
-
206
All
-
208
All
-
209
All
-
210
All
-
211
All
-
212
All
-
213
All
-
214
All
-
215
All
-
216
All
-
217
All
-
218
All
-
219
All
-
220
All
-
221
All
-
222
All
-
22
4. Commissioning
Reset customer totalizer 3
Customer totalizer 3 reset date
Flow rate
Actual velocity
Flowrate percent value
Actual flow meter status
Menu active
Default operator menu index
Fault status
Alarm configuration list
Date of fault log reset
Non optimal measure time
Reset the fault log and faults
Call up acknowledge
Battery alarm level
Reset leakage fault
Reset consumption log fault
Insulation alarm output enable No
Insulation fault hours
Insulation fault counter
Insulation fault appears
Insulation fault disappears
Coil current alarm output enable Yes
Coil current fault hours
Coil current fault counter
Coil current fault appears
Coil current fault disappears
Amplifier alarm output enable Yes
Amplifier fault hours
Amplifier fault counter
SFIDK.PS.026.D9.02
Factory settings
Fix parameter or meter data that not are changeable
No
PS3 production date and time
0
63=all menus active
Totalizer 1
0
254= Alarm 2 to 8 enabled
PS3 production date and time
0
2000-01-01 T 00:00:00
No
10%
No
No
0
0
2000-01-01 T 00:00:00
2000-01-01 T 00:00:00
0
0
2000-01-01 T 00:00:00
2000-01-01 T 00:00:00
0
0
Data range
Yes/no
year-month-day T
hours:minutes:seconds
0 - 1.25 Qn (Q3)
0 - 12500
0-125% (Q4)
0 to 255, binary presented
with
information 1 for bit 0
1: Totalizer 1 or 2 changed or reset,
2: Tariff setting changed or reset,
3: Tariff register changed or reset,
4: Date - time changed,
5: Alarm have been active,
6: Fault log has been reset,
7: Hardware key has been activated,
8: Meter has been power Up
0 to 63, binary presented
with information
1 for bit 0
1: Operator menu,
2: Meter info menu,
3: Service menu,
4: Log menu,
5: Statistic menu,
6: Revenue menu
Totalizer 1, Totalizer 2, Actual Flow rate,
Fault codes, Customer Totalizer
0 to 8191, binary presented
information 1 for bit 0
1: Insulation error,
2: Coil current error,
3: Preamplifier overload,
4: Database checksum error,
5: Low power warning,
6: Flow overload warning,
7: Pulse A overload warning,
8: Pulse B overload warning,
9: Consumption interval warning,
10/L: Leakage warning,
11/E: Empty pipe warning,
12/C: Low impedance (high conductivity)
warning,
13/d: Flow limit warning
0 to 8191,
See 200
year-month-day T
hours:minutes:seconds
Yes/no
0-100%
Yes / No
Yes / No
Yes / No
Yes / No
Yes / No
with