Dealer Calibration - Raymarine i40 Installation And Operation Instructions Manual

Table of Contents

Advertisement

9. Keep the vessel speed below 2 kts and begin to turn the vessel
in a circle.
10. Press the Up button to begin linearization.
11. You will be required to perform a minimum of 2 complete circles.
An alarm will sound upon successful completion.
12. After linearization the align transducer page is displayed. Use
the Up button to increase the alignment angle and the Down
button to decrease the alignment angle.
13. To save your settings and return to normal operation from any
page, simultaneously press and hold the Down and Action
buttons for 2 seconds.
Intermediate calibration
Intermediate calibration allows you to:
• Check the instrument software version.
• Check and if necessary set the instrument status as either Master
or Repeater.
Checking software version and instrument status
During normal operation:
1. Simultaneously press and hold the Down and Action buttons for
4 seconds to display the software version.
60 5
55
4
10
50
45
15
20
40
35
25
30
+
2. Press the Action button to display the instrument status.
Note: The i40 Bidata requires an extra Action button push to
switch from depth instrument status and speed instrument status.
3. Use the Up and Down buttons to change the instrument status
between Master and Repeater.
4. To save your settings and return to normal operation from any
page, simultaneously press and hold the Down and Action
buttons for 2 seconds.

Dealer calibration

Dealer calibration enables you to set:
• User calibration on / off.
• Boat show mode on / off.
• Reset factory defaults.
Changing dealer calibration settings
During normal operation:
1. Simultaneously press and hold the Down and Action buttons for
12 seconds to display the dealer calibration page.
60 5
55
50
10
12
45
15
40
20
35
25
30
+
Getting started
CAL
CAL
CAL
2. Press the Action button to display the user calibration access
page.
3. Use the Up and Down buttons to switch the User calibration
D12415-1
on and off.
Selecting off will disable the user calibration pages.
4. Press the Action button to display the boat show mode page.
5. Use the Up and Down buttons to switch boat show mode on
D12416-1
and off.
Selecting on will put the display into boat show mode.
Note: Boat show mode is only suitable for demonstration
purposes and should NOT be used whilst your vessel is in use.
6. Press the Action button to display the Factory defaults page.
7. To reset your display to factory default settings, use the Up or
Down buttons to change the reset option to Yes.
8. Press the Action button to reset your display to factory defaults
or return to the user calibration access page.
9. To save your settings and return to normal operation from any
page, simultaneously press and hold the Down and Action
buttons for 2 seconds.
D12408-1
D12404-1
D12399-1
CAL
CAL
D12413-1
CAL
CAL
D12397-1
CAL
CAL
D12406-1
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I40 seriesI40 bidataI40 depthI40 speedI40 windE70066 ... Show all

Table of Contents