Cable
Description
2 x4 Mini-SAS cable
776402-001
4 x4 Mini-SAS cable
781579-001
Group D—SAS expander card to rear drive cage
o
Cable
776401-001
12G SAS Expander Card ports
To install the component:
Power down the server (on page 26).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 26).
o
Remove the server from the rack (on page 27).
o
Remove the access panel (on page 27).
4.
Remove the air baffle (on page 32).
5.
Remove the fan cage (on page 29).
6.
Remove the primary PCI riser cage.
7.
IMPORTANT: The 12G SAS Expander Card is not supported in the secondary PCI riser
cage.
Connection to
SAS expander
Port 3
Port 4
Port 5
Port 6
Port 7
Port 8
Description
Connection to SAS
expander
X4 Mini-SAS cable
Port 9
Connection to drive bay
8 SFF Bay 1 Port 1
8 SFF Bay 1 Port 2
8 SFF Bay 2 Port 1
8 SFF Bay 2 Port 2
8 SFF Bay 3 Port 1
8 SFF Bay 3 Port 2
Connection to drive bay
2SFF/3LFF
Hardware options installation 124