Operational Check (Lock must be properly installed, refer to Installation Instructions)
Insert key into outside cylinder and rotate key
The key will retract the latchbolt
Inside lever retracts latchbolt
Enter factory set Emergency code 4321 [
latchbolt (If emergency code does not work refer to Programming Instructions and reprogram
lock with a new master code and emergency code). The unit will relock after 10 seconds
If lock is functioning properly go to Programming Instructions.
If the lock does not function properly refer to troubleshooting page 7.
Lock Operation:
Programming is performed through a 12 digit keypad that has the numbers 0-9, [
The [ # ] acts as the entrance into programming mode (press & hold for 3 seconds). The [ # ] key also
acts as a enter key during programming and is used after each code entry. If the [
reentered within 5 seconds after programming a code, the unit re-enters the programming mode
and looks for the next program code. The [
In normal operating mode.
Note:
1) No programming can be made until the master & emergency codes are changed from the
factory presets. Once the factory preset master or emergency codes are changed they can
not be reprogrammed back into the unit.
2) When changing the master code, if the new master code verification does not match, then the
lock exits programming mode and the previous master code stays valid.
3) During programming mode, the yellow LED will flash continuously at normal rate. To enter
the lock into programming mode, the [ # ] key is held depressed for 3 seconds. The yellow
LED will begin flashing and the [ # ] key can be released. During each entry of the program
codes, the yellow LED will continue flashing. At the end of the last program value, the green
LED will short flash twice and the horn will emit 2 short tones to indicate that valid values
were entered. Pressing the [
sequence and a long red flash and 1 very long tone will result.
If a program value is entered out of range, the long red LED will light and a very long tone will
sound indicating an invalid entry. Programming mode can be reinitiated within 5 seconds of
the error by depressing the [ # ] key otherwise programming mode is exited.
4) After programming mode is exited, the lock always defaults to the standard user mode.
(Passage & Lockout are automatically exited)
5) Upon depression of each key, the yellow LED, if enabled (PCC=32), will light for 50 msec.
The sounder, if enabled (PCC=31) will sound one short tone.
6) Upon 3 (default) successive invalid faceplate entries (PCC=33), the lock will light one long
red flash along with a long tone and the faceplate will inhibit further entries for a
Preprogrammed (10 sec default) time (PCC=34).
During this inhibit time the sounder will produce
one short tone per second.
An ASSA ABLOY Group brand
*
] to unlock the outside lever and retract the
*
] Key acts a finish key after every user code entry
*
] key at any time during programming will exit the program
*
] and [ # ] keys.
] key is
#
Abbreviations Table
MC
Master Code
Program Command Code
PCC
VAL
Value
#
Enter Key
Finish Key
*
def
Default
dis
Disable
EN
Enable
LOC
User Location 1 through 99
2
80-9150-8005-010 (10-12)

Advertisement

loading

This manual is also suitable for:

E890 exit device trim seriesE8850fl mortiseseries