Keypad Programming Commands
General Format
MC#
Audible Keypad Feedback 0=DISABLE, 1=ENABLE (Default =1)
(Hold)
#
MC#
Visual Keypad Feedback 0=DISABLE, 1=ENABLE (Default =1)
(Hold)
#
MC#
Keypad Attempts (1 thru 255) Default = 3 Attempts
(Hold)
#
MC#
Keypad Timeout (1 thru 255 Sec) Default = 10 Sec
#
(Hold)
MC#
Unlock Time (1 to 255 Sec) Default = 4 Sec
(Hold)
#
MC#
Set REX Unlock (1 to 255 Sec) Default = 10 Sec
(Hold)
#
MC#
Set Emergency Unlock Time (1 to 255 Sec) Default = 10 Sec
(Hold)
#
MC#
Features and Options:
1) Error Lockout: The lock will stop accepting key presses after 25 presses or three
successive [
short beep three times with one short red flash (indicating invalid code entry) and
continue to short beep once per second for the duration of the lockout time (no LED will
light). The lock will not accept any key presses during that 10 second (default) time. The
error lockout option overrides the horn disable function (PCC#31).
2) Low Battery Indicator: When the battery voltage drops below (5.8 volts) the lock will
short beep 4 times and allow entry. If the battery voltage drops below 5.4 volts (Blackout
Mode), 4 short beeps followed by 4 long tones will sound, but the lock will not open. The
lock will function for the Supervisor and Emergency Codes only. See page 7 for the
battery replacement.
3) Request To Enter Input: A normally open contact that when closed will unlock the lock
for 5 seconds. Upon activation, the lock will emit one short green flash per second. This
feature requires hardwiring to the lock. This option will be sold as a kit which includes a
wiring harness that connects to the board. When the lock is in passage mode, activating
the request to enter will disable passage mode and relock the lock.
4) Peizo Sounder: 85dBA minimum. Short tone with each keystroke. Can be disabled by
Supervisor code.
5) LED Indicator: All three LED's can be disabled by the Supervisor Code; however they
are still active in the programming mode. Ye llow-programming mode, Green- successful
entry, Red-Indicates input error.
6) Re-lock Duration: The duration that the lock remains unlocked can be adjusted from 1 to
255 seconds. Default at 4 seconds.
7) Hardwire: The board comes standard with a 2 pin input connector to allow hardwiring
an external 9 VDC power supply (Part # 784). This option is sold as a kit including a
wiring harness that connects to connectors provided on the board.
An ASSA ABLOY Group brand
PCC
VALUE
31#
VAL #
32#
VAL #
33#
VAL #
34#
VAL #
44#
VAL #
45#
VAL #
46#
VAL #
*
] entries without a valid code. Upon the third incorrect entry, the lock will
These Program Modes
and User Codes can be
programmed with the
Supervisor Code (SC) or
the Master Code (MC)
80-9150-8005-010 (10-12)
6