Operations and Maintenance Manual
E4H Series Water Purification Machine

2.3.2 DLX Electrical System

The DLX series E4H's include the AccuTrak® RO solid state controller. The AccuTrak
• 
includes a menu screen for selecting the operation mode of the RO. The RO must be in either
"Auto" or "Hand" position for the high pressure pump to start.
Connect the control circuit power to 110 VAC, 60 Hz, or 220 VAC, 50 Hz, single phase
power.
Connect the three-phase power in to the motor starter 3-pole contacts (230/460 VAC
or 380 VAC as appropriate). Ensure that the power supplied matches the motor voltage and
phase requirements. Check the tag (located on the motor starter) that indicates the factory
wiring. A separate, fused disconnect for the motor wiring is required with proper protection for
the HP and amp draw of the RO and CIP motors (provided by others). Please refer to single-
line drawing for further detail.
 
 
 
 
 
 
 
 