19.3.4 Setting own ship's parameters
Set parameter values of own ship by using the "Ship's Parameters" dialog.
19.3.4.1 Displaying the "Ship's Parameters" dialog
When you select [Ship's Parameters] in the classification pane, the "Ship's Parameters" dialog is
displayed in the edit/result pane.
19.3.4.2 Setting own ship's parameters
Set the following items in the "Ship's Parameters" dialog.
Setting Item
Ship's Name
Length (of ship)
Beam (ship's width)
Height from keel to MAX point
Keel-Trans
(distance between the transducer
and the keel)
MAX Course Change
(limit value of course change
angle)
MAX Speed Limit
MIN Speed Limit
MAX ROT
MIN ROT
MIN Turn Radius
Section 19 Adjusting and Setting up Equipment (for Services)
Description of Setting
Enter own ship's name in the box.
Enter own ship's length in the box.
Enter own ship's beam in the box.
Enter the height of the ship from the keel to the
maximum point in the box.
Enter the distance between the transducer of the
depth sounder and the keel. (Required when
displaying the water depth with the keel fixed)
Enter the limit value of the course change angle
of the planned route in the box.
Enter the ship's maximum speed in the box.
Enter the ship's minimum speed in the box.
Enter the maximum rate of turn in the box.
Enter the minimum rate of turn in the box.
Enter the minimum turn radius in the box.
19-28
Setting Value
Max. 20 characters
1.0 to 1022.0 m
1.0 to 126.0 m
1.0 to 126.0 m
0.0 to 20.0 m
20.0 to 359.9°
10.0 to 99.9 kn
0.0 to 89.9 kn
30.0 to 600.0°/min
0.0 to 570.0°/min
0.00 to 9.99 NM