You can see this type plate when you open the front cover of the NCU 720.2 PN and
NCU 730.2 PN.
See also
PROFINET cables (Page 70)
6.6
PROFIBUS–DP/MPI interfaces X126, X136
Properties
● Isolated RS 485 interface
● Max. data rate 12 Mbaud
● Supports master/slave operation
● PROFIBUS address is set via configuration
● OLPs (6GK1502-1AA00) are not permitted
Pin assignment for X126, X136
Table 6-8
Pin
1
2
3
4
5
6
7
8
9
The 1P5 voltage is provided exclusively to supply the bus terminal.
Signal type: VO = Voltage output (power supply) O = Output B = Bidirectional
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
Note
In addition to the DP (distributed I/Os) protocol, X136 can also transmit the MPI (multi-
point interface) protocol (software-controlled).
PROFIBUS DP interfaces (X126, X136)
Signal name
Signal type
Nc
-
M
VO
2RS_DP
B
2RTS_DP
O
1M
VO
1P5
VO
P24_SERV
VO
2XRS_DP
B
Nc
-
6.6 PROFIBUS–DP/MPI interfaces X126, X136
Meaning
-
Ground to P24_SERV
RS485 differential signal
Request to Send
Ground to 1P5
5 V power supply for bus terminal, external, short circuit-proof
24 V for teleservice, short circuit-proof, 150 mA maximum
RS485 differential signal
-