Interfaces - Siemens SINUMERIK 840D sl Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

11.2.3

Interfaces

Power supply X124
Table 11-2
Pin assignment for X124
Terminal
+
+
M
M
Max. connectable cross-section: 2.5 mm
Type: Screw-type terminal
Note
The two "+" and "M" terminals are jumpered in the connector and not in the device. This
ensures that the supply voltage is looped through.
The current consumption increases by the current consumption of DRIVE-CLiQ and the
digital outputs.
DRIVE-CLiQ interfaces X100 - X103
Table 11-3
Features
Connector type
Cable type
Max. cable length
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
Function
Electronics power supply
Electronics power supply
Electronic ground
Electronic ground
2
Characteristics of X100 - X103
Specification
DRIVE CLiQ plug connector
DRIVE-CLiQ standard (inside the control cabinet)
MOTION CONNECT (outside the control cabinet)
70 m
Technical specifications
Voltage: 24 V DC (20.4 V - 28.8 V)
Current consumption: max. 0.8 A (without load)
Max. current via jumper in connector:
20 A at 55 °C