Technical Data

Table 10-1
Safety
Protection class
Degree of protection to EN 0529
Certifications
Pollution degree
Cooling
Mounting position
Mechanical environmental conditions
Transportation (in transportation
packaging)
Storage
Table 10-2
Main memory
SIMATIC S7 - integrated
Input voltage
Power consumption, max.
Power loss
Dimensions (WxHxD)
Weight, approx.
Table 10-3
Main memory
SIMATIC S7 - integrated
Input voltage
Power consumption, max.
Power loss
Dimensions (WxHxD)
Weight, approx.
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
General technical data
IP20 or IPXXB with option slot cover or option module inserted
Electrical and mechanical data (1)
NCU 710.2
512 MB DRAM
1 MB SRAM
PLC 317-2 DP
24 VDC
170 W
22 W
50 x 455 x 272 mm
2.9 kg
Electrical and mechanical data (2)
I (protective conductor) as per EN 61800-5-1
CE, cULus
Open-circuit-ventilated
Vertical
2M3 according to EN 60721-3-2
1M2 according to EN 60721-3-1
NCU 720.2
1 GB DRAM
1 MB SRAM
PLC 317-2 DP
24 VDC
174 W
25 W
50 x 455 x 272 mm
2.9 kg
NCU 730.2
1 GB DRAM
1 MB SRAM
PLC 317-2 DP
24 VDC
216 W
55 W
50 x 455 x 272 mm
3.6 kg
10
2
NCU 720.2 PN
1 GB DRAM
1 MB SRAM
PLC 319-3 PN/DP
24 VDC
216 W
55 W
50 x 455 x 272 mm
3.8 kg
NCU 730.2 PN
1 GB DRAM
1 MB SRAM
PLC 319-3 PN/DP
24 VDC
225 W
65 W
50 x 455 x 272 mm
3.8 kg