Access Point Installation Procedures
corresponding holes on the junction box (see
holes).
3.
Plug the Ethernet cable into the RJ-45 port (and plug the power cord into the power port, if
applicable) on the back of the AP before mounting the AP on the bracket.
4.
Place the back of the AP against the mounting bracket so that the bracket side rails fit into the
rail slots on the back of the AP and the locking screw hole in the AP aligns with the locking
tab. Slide the AP down until the AP rests on the locking tab, and screw in the locking screw
through the locking tab and locking screw hole.
would look like with the mounting bracket in place.

LAN/Console Connections

The WS-AP3710 has both a LAN and a Console port. Refer to
location of these ports. The WS-AP3725 has two LAN ports and a Console port. Refer to
on page 1-7 for the location of these ports.
During administration and maintenance through the LAN or Console, the AP must have a power
connection through either an Ethernet PoE cable or a DC power supply.

Power Connections

The AP can be powered in one of the following ways:
Power over Ethernet (PoE)
Power is provided through the RJ45 Ethernet port (LAN port) on the top of the AP. This is the
preferred method of powering the AP on ceiling and high wall installations.
Power by external power supply
Where a PoE-capable Ethernet connection is unavailable or impractical, an external 48V DC
power supply (WS-AP3X48-MR) may be ordered separately to power the AP from a standard
AC wall outlet. For more information on the installation process, see
Power Supply to the AP3710/AP3725

Connecting the DC Power Supply to the AP3710/AP3725

There is no wall mount for the WS-AP3X48-MR 48V DC power supply. To connect the power
supply to the AP for everyday operation, mount the AP and plug in the power supply as
described in
configuration and maintenance, plug the power cable from the DC power supply into the DC
connector on the top of the AP.
2-6 Installation
Warning: If the screw is not inserted as described in this step, there is a strong risk the
Enterasys Wireless AP3710/AP3725 will fall from the bracket.
Mounting the AP3710/AP3725 to a
DRAFT
Figure 2-3
for location of junction box screw
Figure 2-4
on page 2-5 shows what the AP
Figure 1-1
below.
Wall. If you have taken the AP off its mount for
on page 1-3 for the
Figure 1-5
Connecting the DC