Wiring
Prepare the power source for exclusive with the air conditioner.
The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation.
Remark: All the wiring must be based on the wiring nameplate which is shown on the model.
CAUTIONS
Perform the wiring with su cient capacity. Installation places legally require a short circuit isolator to be attached to
prevent electrical shock.
• Do not extend the power cable code by cutting.
• Power voltage should be in the range of 90%~110% of rated voltage.
• The plug of the air conditioner takes a grounding leg, and clients should use a grounding socket so that the air conditioner
can be grounded e ciently.
• If the power cord is damaged, replacement should be conducted by quali ed technician or a serviceman.
NOTE
Remark per EMC Directive 89/336/EEC
To prevent icker impressions during the start of the compressor (technical process), following installation conditions do apply.
1. The power connection for the air conditioner has to be done at the main power distribution.
The distribution has to be of a low impedance, normally the required impedance reaches at a 32 A fusing point.
2. No other equipment has to be connected with this power line.
3. For detailed installation acceptance, please refer to your contract with the power supplier if restrictions do apply for
products like washing machines, air conditioner or electrical ovens.
4. For power details of the air conditioner, refer to the rating plate of the product.
5. For any question, contact your local dealer.
CAUTIONS
• Never modify the unit by removing any of the safety guards or by bypassing any of the safety interlock switches.
• Connect the connecting cable correctly and connect the connecting cable to terminal as identi ed with their respective marks.
• Do not scratch the conductive core & inner insulator of power supply cables and do not deform or smash on the surface
of cables.
Electrical Connections
All electrical wiring and connections must comply with local codes and standards. Power supply cord and interconnection
cord used must not be lighter than Polychloroprene sheethed cord (245 IEC 57 or H05RN-F).
Disconnecting device must have a contact separation of at least 3 mm.
Indoor Unit : TVHC09DSAAAR
OPTIONAL:
4
CHOOSE ONE BY THE
TRANSFORMER.
2
4
14
ENGLISH
J440-EN.indd 14
3
3
5
P_1
OPTIONAL:
Outdoor Unit : TVHC09DSAAAR
3
11
3
4
~
+
~
+
-
-
~
~
ORANGE
CAP ACITOR
FILTER
3
L
N
S
2
2/14/08 1:26:49 PM