York TCGD18 THRU 60 Technical Manual

York TCGD18 THRU 60 Technical Manual

Split-system air conditioners 13 seer – r-410a
Hide thumbs Also See for TCGD18 THRU 60:

Advertisement

TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
13 SEER – R-410A
MODELS:
TCGD18 THRU 60
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)
LISTED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System

DESCRIPTION

The 13 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG's complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-on coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.

FEATURES

• QUALITY CONDENSER COILS - The coil is constructed
of aluminum microchannel tubing and enhanced aluminum
fins for increased efficiency and corrosion protection.
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure, temperature, and
externally by a factory installed high pressure switch. This
is accomplished by the simultaneous operation of high
pressure relief valve and a temperature sensor which pro-
tects the compressor if undesirable operating conditions
occur. A liquid line filter-drier further protects the compres-
sor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, and a single panel covering the electrical con-
trols make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
359315-YTG-B-0408

Advertisement

Table of Contents
loading

Summary of Contents for York TCGD18 THRU 60

  • Page 1 Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com Additional rating information can be found at www.ahridirectory.org FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE...
  • Page 2 359315-YTG-B-0408 Physical and Electrical Data TCGD18 MODEL S41S1(H) Unit Supply Voltage Normal Voltage Range Minimum Circuit Ampacity Max. Overcurrent Device Amps Min. Overcurrent Device Amps Compressor Type Rated Load Compressor Amps Locked Rotor Crankcase Heater Fan Motor Amps Rated Load Fan Diameter Inches Rated HP Fan Motor...
  • Page 3 Additional R-410A Charge / Orifice Size for Various Matched Systems TCGD18 Outdoor Unit S41S1(H) 0.048 / 902 Required Orifice or TXV Factory Charge, lbs-oz 3 - 3 Indoor Coil 48 + 0 FC/MC/PC/UC18A3X 902 + 0 48 + 0 FC/MC/PC/UC18B3X 902 + 0 –...
  • Page 4 359315-YTG-B-0408 Additional R-410A Charge / Orifice Size for Various Matched Systems (Continued) TCGD18 Outdoor Unit S41S1(H) 0.048 / 902 Required Orifice or TXV Factory Charge, lbs-oz 3 - 3 Indoor Coil – AHP/SHP60D3X – – AV36C3X – – AV/SV48D3X – –...
  • Page 5 COOLING CAPACITY - With Air Handler Coils AIR HANDLER UNIT MODEL MODEL TCGD18S41S1(H) MA08B MA08B TCGD24S41S1(H) MA08B MA08B MA12B TCGD30S41S1(H) MA12B MA12B TCGD36S41S1(H) MA14D MA16C TCGD42S41S1(H) MA14D MA16C MA16C MA20D TCGD48S41S1(H) MA16C MA20D MA20D TCGD60S41S1 MA20D TCGD18S41S1(H) MV12B MV12B TCGD24S41S1(H) MV12B MV12B MV12B...
  • Page 6 359315-YTG-B-0408 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER UNIT MODEL MODEL AHP18 TCGD18S41S1(H) F4FP024 AHP30 TCGD24S41S1(H) F4FP036 AHP30 TCGD30S41S1(H) AHP36 F4FP040 AHP36 TCGD36S41S1(H) AHP42 F5FP048 AHP42 TCGD42S41S1(H) F5FP048 AHP/SHP48 AHP/SHP60 TCGD48S41S1(H) F5FP048 F5FP060 AHP/SHP60 TCGD60S41S1 F5FP060 Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
  • Page 7 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** UNIT MODEL CFM RANGE (Min.-max.) 450 - 750 TCGD18S41S1(H) 450 - 750 450 - 750 600 - 1000 600 - 1000 600 - 1000 600 - 1000 TCGD24S41S1(H) 600 - 1000 600 - 1000 600 - 1000 600 - 1000...
  • Page 8 359315-YTG-B-0408 COOLING CAPACITY - With Variable Speed Furnaces VARIABLE SPEED UNIT MODEL FURNACE MODEL PV8*A12 PV9*A12 TCGD18S41S1(H) P(C,V)9*B12 PV8*A12 PV9*A12 PV8*A12 PV9*A12 P(C,V)9*B12 PV8*A12 PV9*A12 P(C,V)9*B12 TCGD24S41S1(H) PV8*A12 PV9*A12 P(C,V)9*B12 PV8*A12 PV9*A12 P(C,V)9*B12 PV8*A12 PV9*A12 PV8*B16 P(C,V)9*B12 PV8*C16 PV8*C20 P(C,V)9*C16 P(C,V)9*C20 PV8*A12 PV9*A12...
  • Page 9 COOLING CAPACITY - With Variable Speed Furnaces (Continued) VARIABLE SPEED UNIT MODEL FURNACE MODEL PV8*C20 P(C,V)9*C16 P(C,V)9*C20 P(C,V)9*D20 TCGD36S41S1(H) PV8*C16 PV8*C20 P(C,V)9*C16 P(C,V)9*C20 PV8*B16 PV8*C20 P(C,V)9*C16 P(C,V)9*C20 PV8*C16 PV8*C20 TCGD42S41S1(H) P(C,V)9*C16 P(C,V)9*C20 P(C,V)9*D20 PV8*C16 PV8*C20 P(C,V)9*C16 P(C,V)9*C20 PV8*C16 PV8*C20 P(C,V)9*C16 P(C,V)9*C20 P(C,V)9*D20 TCGD48S41S1(H)
  • Page 10 359315-YTG-B-0408 ACCESSORIES Refer to Price Manual for specific model numbers. HARD START KIT - Required when using TXV indoor coil. Also, provides increased starting torque for areas with low voltage. Model Source 1 Kit numbers S1-2SA06708606 S1-2SA06721706 S1-2SA06705906 S1-2SA06708906 S1-2SA06708806 S1-2SA06708806 S1-2SA06707906 OFF CYCLE TIMER DELAY - Provides a 5-minute off cycle...
  • Page 11 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 12 359315-YTG-B-0408 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 13 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 14 359315-YTG-B-0408 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 15 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 16 359315-YTG-B-0408 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 17 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 18 NOTES Subject to change without notice. Printed in U.S.A. 359315-YTG-B-0408 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: 359315-YTG-A-0208 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069...

Table of Contents