SIA Feature Programming
Section
Exit Time
[005]>[001], option 3
Exit Delay Restart
[018], option 7
Auto Stay Arm on Un-vacated
Premises
[001]>[001]-[128] Zone type 05,
06,09
Exit Time and Progress
Annunciation/Disable or Remote
Arming
[861]>[001]-[005], option 4
Entry delay(s)
[005]>[001]-[008], options 1 and
2
Abort Window for Non-Fire zones
[002]>[001]-[128], option 7 ON
Abort Window Time - for Non-
Fire zones
[377]>[002], option 1
Abort Annunciation
Duress Feature
[*][5]> master code> user 2-95>
5> 2
Cancel Window
[377]>[002], option 6
Cancel Annunciation
[308]>[001], option 8
Cross Zoning
[042]>Selection 3, option 002
Burglary Verification Timer
[005]>[000], option 3
Swinger Shutdown for Alarms
[377]>[001], option 1
Swinger Shutdown Enable
[002]>[001] - [128], option 6 ON
24-Hr. Auto-verified Fire
[001]>[001]-[128], Zone type 025
ON
Call Waiting Cancel
[382], option 4 OFF
System Test:
[*][6] Master Code, option 04
Walk Test Mode:
[*][8][Installer code][901]
Walk Test Communications
[382], option 2
Walk Test Start/ End Reporting
Codes
[308][401], options 1 and 2
PowerSeries Neo Installation Guide
Comments
Access to Entry and Exit delays and Bell Time Out for the system.
Opening a Delay zone door after it has already been opened and closed during an exit delay restarts the
exit delay timer.
Function key: Forces the system to arm in Stay mode if the occupant does not exit the premises after
pressing the Away function key.
System times and audible exit beeps can be disabled when using the wireless key to stay arm the
system. When away arming, audible exit beeps can not be disabled.
Access to entry and exit delays and bell time out for the system
Note: Combined entry delay and communications delay (abort window) shall not exceed 60s.
Access to zone attributes, i.e., swinger shutdown, transmission delay and cross zone. May be disabled
by zone or zone type.
Access to the programmable delay before communicating alarms
Note: Combined entry delay and communications delay (abort window) shall not exceed 60 seconds.
An audible tone is generated when an alarm is aborted during the abort window.
When this feature is enabled, selected user codes send a duress reporting code to the central station
when used to perform any function on the system. Section [019], option [6] must be enabled.
Access to the communications cancel window. Minimum duration must be 5 minutes.
Access to the reporting code for Alarm Canceled.
Enables cross zoning for entire system. Zones can be enabled for cross zoning via zone attribute option
8 in sections [002][101] - [128].
Access to the programmable Cross Zone timer.
Access to the swinger shutdown limit for zone alarms
For all non-fire zones, shut down at 1 to 6 trips.
Access to swinger shutdown, transmission delay and cross zone attributes. Zone attribute option 6
(Swinger Shutdown enabled) is ON.
Access to 24-Hr. Auto-verified Fire
Activates if Not restored within the specified time.
Access to the dialing sequence used to disable call waiting. Call waiting string can be programmed in
[304]
The system activates all keypad sounders, bells or sirens for 2 seconds and all keypad lights turn on.
Refer to user manual (part no. 29008365).
This mode is used to test each zone on the system for proper functionality.
Enables communication of zone alarms while walk test is active.
Access to the reporting codes for walk test start and end times.
- 24 -
Range/Default
Requirement
Range:45- 255
Required
seconds
(programmable)
Default: 60 sec.
Default: Enabled
Required
If no exit after full
arm
Required
Default: Enabled
Default: Enabled
Allowed
Required
Range: 30 sec. to 4
min.
(programmable)
Default: 30 sec.
Required
Default: Enabled
Range: 00 - 45 sec.
Required
Default: 30 sees
(programmable)
Hard-coded ON
Required
Default: N
Required
Range: 005-255
Default: 005
A Cancel was
Required
transmitted
Default: Enabled
Programming
required
Required
Default: Disabled
Range: 000-255 sec.
Allowed
Default: 60 seconds
Required
Default: 2 trips
(programmable)
Non-police
response zones
Allowed
Default: Enabled
Must choose zone
Required
type for application
Depends on user
phone line
Required
Default: Disabled
Default: Disabled