C
ONTENTS
Before installation.............................................................................. 1
Selecting installation site................................................................... 1
Check list........................................................................................... 1
Preparations before installation......................................................... 2
Indoor unit installation ....................................................................... 2
Refrigerant piping work ..................................................................... 2
Vacuum drying of installation ............................................................ 3
Drain piping work .............................................................................. 3
Drain check ....................................................................................... 3
Field wiring ........................................................................................ 3
Field setting....................................................................................... 4
Test operation.................................................................................... 4
Internal wiring - parts table................................................................ 5
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE
REFERENCE.
IMPROPER
INSTALLATION
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE
AND INFORMATION.
B
EFORE INSTALLATION
Decide upon a line of transport.
Leave the unit inside its packaging while moving, until reaching
the installation site. Where unpacking is unavoidable, use a sling
of soft material or protective plates together with a rope when
lifting, to avoid damage or scratches to the unit.
Caution concerning refrigerant series R-410A:
-
The connectable outdoor units must be designed exclusively
for R-410A.
-
If outdoor units for R22, R-407C are connected, the system
will not work properly.
Accessories
Check if the following accessories are included with your unit.
T A L
IN S
a i r
e m
y s t
i t S
S p l
A co
os de
re lh
A pa
1
F 7 V
1 2 5
F 7 V
1
F D Y
2 0 0
1
F D Y
F 7 V
2 5 0
F D Y
Installation manual, Operation manual
Installation manual
1
OR
ATTACHMENT
L
N U A
A L
M A
A N U
IO N
N M
L A T
T IO
E R A
O P
r s
r s
o n e
o n e
d i t i
d i t i
c o n
c o n
a i r
e m
y s t
i t S
S p l
is h
is h
En gl
En gl
ua l
ua l
m an
m an
tio n
s
tio n
s
on er
on er
al la
al la
In st
nd iti
In st
nd iti
ai r co
sc h
ai r co
sc h
De ut
De ut
te m
te m
S ys
itu ng
S ys
itu ng
S pl it
S pl it
an le
an le
e
e
tio ns
er ät
tio ns
er ät
al la
lim ag
al la
lim ag
In st
e K
ça is
In st
e K
ça is
re ih
Fr an
re ih
Fr an
B au
n
B au
n
S pl it-
la tio
S pl it-
la tio
st al
S pl it
st al
S pl it
d' in
d' in
ue l
ue l
sé rie
sé rie
M an
de la
s
M an
de la
s
rla nd
rla nd
Ne de
Ne de
eu rs
eu rs
at is
in g
at is
in g
le id
le id
C lim
C lim
ha nd
rs
ha nd
rs
tio ne
tio ne
ta ge
ta ge
M on
on di
ño l
M on
on di
ño l
ai rc
ai rc
Es pa
Es pa
ee m
ee m
sy st
n
sy st
n
ac ió
ac ió
S pl it-
S pl it-
st al
S pl it
st al
S pl it
de in
de in
ua l
se rie
ua l
se rie
no
no
M an
ai re
Ita lia
M an
ai re
Ita lia
s de
s de
do re
on e
do re
on e
io na
la zi
io na
la zi
nd ic
st al
pl it
nd ic
st al
pl it
d' in
rie S
d' in
rie S
A co
ua le
ri se
ua le
ri se
Èο
Èο
M an
za to
ÏÏ ËÓ
M an
za to
ÏÏ ËÓ
at iz
at iz
C lim
˘
C lim
˘
Ù· Û
Ù· Û
Ù¿ Û
it
Ù¿ Û
S pl
S pl
it
ÂÁ η
ÂÁ η
ο
ο
‰È Ô
ÙÈ Û ÙÈ
gu es
‰È Ô
ÙÈ Û ÙÈ
gu es
ÂÈ Ú›
ÂÈ Ú›
K ÏÈ Ì·
Po rtu
K ÏÈ Ì·
Po rtu
E Á¯
E Á¯
aç ão
aç ão
st al
st al
de in
S pl it
de in
S pl it
ua l
sé rie
ua l
sé rie
k
k
M an
do da
Da ns
M an
do da
Da ns
io na
io na
nd ic
dn in
g
nd ic
dn in
g
ar co
ve jle
ar co
ve jle
st em
st em
tio ns
os de
tio ns
al la
lt sy
al la
lt sy
op de
re lh
op de
In st
A pa
In st
ag i
ag i
aa nl
aa nl
K lim
K lim
1
F 7 V
1 2 5
F 7 V
1
F D Y
2 0 0
1
F D Y
F 7 V
2 5 0
F D Y
Split System air conditioners
Note to the installer
Page
Be sure to instruct the customer how to properly operate the system
and show him/her the attached operation manual.
S
ELECTING INSTALLATION SITE
1.
Select an installation site where the following conditions are
fulfilled and that meets your customer's approval.
Where the ceiling is strong enough to support the weight of
the unit and to prevent vibration and noise generation.
Where sufficient clearance for maintenance and service can
be ensured (Refer to
The power supply intake (1), drain connection (2), gas pipe
(3) and liquid pipe (4) connection should always be
accessible for maintenance and service.
Where piping between indoor and outdoor units is possible
within the allowable limit. (Refer to the installation manual for
the outdoor unit.)
There is no danger of fire due to leakage of flammable gas.
Ensure that water can not cause any damage to the location
OF
in case it drips out of the unit (e.g. in case of a blocked drain
pipe).
Please consult with your dealer for installing in a special
environment (e.g. a place in oily surroundings, a place with
sulfide gas, a place where chemicals are used nearby, a
place with high voltage fluctuations, a place with volatile
flammable gas, a place in which machinery generates
electromagnetic waves.
2.
Use suspension bolts for installation. Check whether the ceiling
is strong enough to support the weight of the unit or not.
If there is a risk, reinforce the ceiling before installing the unit.
C
HECK LIST
For the following items, take special care during construction and
check after installation is finished
Tick
when
checked
Is the indoor unit securely installed?
Is the gas leakage checked?
Is the heat insulation:
For the gas pipe adequate?
For the liquid pipe adequate?
For the indoor side extension drain hose adequate?
Does the drain flow out smoothly?
Are the line voltages within tolerance?
Is the earth wire earthed?
Are wiring and piping correct?
Are the air inlet and outlet of the indoor and outdoor unit not
blocked?
Are refrigerant piping length and additional refrigerant charge
noted down?