Note
The number of SCALANCE X Industrial Ethernet devices connected in a line influences the
frame delay time.
When a frame runs through the SCALANCE X-100 media converter, this is delayed typically
by approximately 8 µs by the cut through function of the internal switch.
At 100% bus load, these times can be higher depending on the system (maximum 140 µs).
Note
Temperature code for c-UL-us for hazardous locations, FM and ATEX Zone 2
You will find the temperature code "T.." or the maximum ambient temperature "Ta: .." on the
type plate.
7.2
SCALANCE X101-1LD
Table 7- 2
Technical specifications of the SCALANCE X101-1LD
Technical specifications
Order number
SCALANCE X101-1LD
Attachment to Industrial Ethernet
Quantity
Design
Properties
Transmission speed
Optical connectors
Quantity
Design
Properties
Transmission speed
Permitted cable lengths (Industrial
Ethernet)
0 ... 85 m
0 to 100 m
SCALANCE X-100 media converter
Operating Instructions, 04/2016, C79000-G8976-C346-02
6GK5101-1BC00-2AA3
1
RJ-45 jack with MDI-X pinning
Full duplex
100 Mbps
1
BFOC socket
Full duplex to 100 Base-LX
100 Mbps
Alternative combinations per length range
Max. 85 m IE FC TP Marine/Trailing Cable with IE FC RJ45 Plug 180
Max. 75 m IE FC TP Marine/Trailing Cable + 10 m TP Cord via
IE FC RJ45 Outlet
Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180
Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet
Technical specifications
7.2 SCALANCE X101-1LD