Sterndrive Water Inlets Check; Section 4 - Maintenance - Mercury 2.8 Diesel Operation & Maintenance Manual

Sterndrive models
Hide thumbs Also See for 2.8 Diesel:
Table of Contents

Advertisement

e.
Install the sealing washer and drain plug, if equipped.
9.
After the seawater has completely drained, apply sealant to the threads of the drain plugs or fittings (if equipped). Install
and tighten the drain plugs or fittings.
Tube Ref No.
Perfect Seal
19
10. Connect all hoses. Tighten the hose clamps.

Sterndrive Water Inlets Check

1.
Obtain a piece of wire the appropriate size to insert into the water inlets holes.
2.
Insert the wire in and out of the sterndrive water inlets to ensure that they are open and to remove debris or marine growth.
Do not scrape the sterndrive paint.
3.
Remove the wire from the sterndrive and retain for periodic water inlet checks.
a
90-8M0113987
DECEMBER 2015
eng
Typical
Description
b
22495
Where Used
Drain plug or fitting threads
a -
Dual water pickup water inlets
b -
Side pickup water inlets

Section 4 - Maintenance

37290
Part No.
92-34227Q02
Page 61