Event Log - NEC NovaScale R630 User Manual

Table of Contents

Advertisement

Event Log

"The NMS Service terminated unexpectedly." is recorded in the system event log:
→ Although the following log may be recorded in the system event log when starting the system, or after
exchanging PCI modules, there is no real problem on operation. Change of a setup with PROSet II
will become invalid if NMS service stops, but you can change a setup normally because NMS service
will be automatically started when PROSet II is started.
"Source:
Event ID:
Description: The NMS service terminated unexpectedly. This has occurred 1 time(s). The following
iANSMiniport-related logs are recorded in the system event log:
→ The logs of the source "iANSMiniport" are the logs about the duplex of the network. The following
logs may be recorded in the system event log after starting the system or after setting duplex, but there
is no problem on operation.
Source:
Type:
Event ID:
Description: Initializing "Virtual Team Adaptor" that lack adapter "Number of missed adaptors."
Source:
Type:
Event ID:
Description: "Physical Adaptor" is invalid in the team.
Source:
Type:
Event ID:
Description: The following adapter link is not connected: "Physical Adaptor."
Source:
Type:
Event ID:
Description: "Virtual Team Adaptor": the last adapter lost the link.
Source:
Type:
Event ID:
Description: The primary adapter did not detect the following probe: "Physical Adaptor." Reason:
The log above gets output in the process of system start up or dual mode setting. When the log is
recorded, there is no problem to the system by the above warning if the status of the adapter in the
team is "Active" or "Standby." For the status of the adapter, check in properties of the team adapter
from the device manager.
EvntAgnt log is recorded in the application event log:
→ This event does not have any influence to the system not to SNMP services. Thus no measurement is
required.
Source:
Event ID:
Description: TraceFileName parameter not located in registry; Default trace file used is .
Source:
ID:
Description: TraceLevel parameter not located in registry; Default trace level used is 32.
Service Control Manager
7031
corrective action will be taken in 0 milliseconds: No action."
iANSMiniport
Warning
35
Check if all adapters exist and function properly.
iANSMiniport
Warning
13
iANSMiniport
Warning
11
iANSMiniport
Error
16
The team network lost the connection.
iANSMiniport
Warning
22
The team may be divided.
EvntAgnt
1003
EvntAgnt
1015
7-17