Magnavox 19MDTR20 Service Manual page 45

With built-in vcr/dvd player
Hide thumbs Also See for 19MDTR20:
Table of Contents

Advertisement

Power Supply / AV CBA Top View < TV/VCR Section >
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
2
If Main Fuse (F2601) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
VR2601
+B ADJ
4A 125V
1-6-23
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK
OF FIRE, REPLACE ONLY WITH SAME TYPE 4A, 125V FUSE.
ATTENTION: UTILISER UN FUSIBLE DE RECHANGE DE
MÊME TYPE DE 4A, 125V.
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT, AN ISOLATION TRANSFORMER MUST BE USED.
ALSO, IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY, WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT, A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
WF18
TP2203
DVD-Y
WF18
TP2204
DVD-C
1-6-24
BTD850F01021A