Main 6/6 Schematic Diagram < TV/VCR Section >
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
CAUTION ! :
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
4A 125V
ATTENTION : Utiliser un fusible de rechange de même type de 4A, 125V.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
Voltage indications for PLAY, REC and DVD modes
on the Schematic Diagrams are as shown below:
1
"
" = SMD
5.0
The same voltage for
PLAY, REC & DVD modes.
1-11-12
PLAY mode
2
3
5.0
~
REC mode
(2.5)
DVD mode
<
>
0
Indicates that the voltage
is not consistent here.
VOLTAGE CHART (Power off mode)
Ref. No.
1
2
3
4
IC1601
12.0
10.9
0.3
1.6
1
2
3
Ref. No.
3.1
0
1.9
IC1682
Ref. No.
S
D
G
Q1601
0
164.2
1.8
E
C
B
Ref. No.
Q1221
5.3
5.3
3.5
Q1602
0
1.8
0.3
Q1604
6.8
10.9
7.4
Q1605
0
8.0
0
Q1606
9.2
9.2
8.6
Q1607
0
0.1
0.7
Q1609
5.9
8.2
6.5
Q1613
0.8
8.1
1.4
Q1614
0.9
8.1
1.4
Q1681
0.4
3.2
0.9
Q1682
0.9
0.3
3.2
Q1683
0.9
0.8
3.2
0.3
3.2
0.9
Q1688
T0102MCSCM6