Magnavox 19MDTR20 Service Manual page 134

With built-in vcr/dvd player
Hide thumbs Also See for 19MDTR20:
Table of Contents

Advertisement

Main 6/6 Schematic Diagram < TV/VCR Section >
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F2601) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK
OF FIRE, REPLACE ONLY WITH SAME TYPE 4A, 125V FUSE.
ATTENTION: UTILISER UN FUSIBLE DE RECHANGE DE
4A/125V
MÊME TYPE DE 4A, 125V.
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
1-8-17
Voltage indications for PLAY, REC and DVD modes
on the Schematic Diagrams are as shown below:
1
2
3
5.0
~
5.0
(2.5)
<
>
0
THE SAME VOLTAGE FOR
"
" = SMD
INDICATES THAT THE VOLTAGE
PLAY,REC & DVD MODES.
IS NOT CONSISTENT HERE.
PLAY MODE
REC MODE
DVD MODE
1-8-18
VOLTAGE CHART (Power off mode)
2
3
Ref. No.
1
4
IC601
12.0
1.6
10.9
0.3
Ref. No.
1
2
3
3.1
0
1.9
IC682
S
D
G
Ref. No.
Q601
0
164.2
1.8
Ref. No.
E
C
B
Q221
5.3
5.3
3.5
Q602
0
1.8
0.3
Q604
6.8
10.9
7.4
Q605
0
8.0
0
Q606
9.2
9.2
8.6
Q607
0
0.1
0.7
Q609
5.9
8.2
6.5
Q613
0.8
8.1
1.4
Q614
0.9
8.1
1.4
Q681
0.4
3.2
0.9
Q683
0.8
3.2
0.9
Q688
0.3
3.2
0.9
T0006SCM6

Hide quick links:

Advertisement

Table of Contents
loading