Aiwa XR-EM70 Service Manual page 34

Hide thumbs Also See for XR-EM70:
Table of Contents

Advertisement

QQ
<AM Adjustment>
3 7 63 1515 0
For AM adjustment, do wiring and connection as in the following.
Standard Signal Generator
4. IF adjustment (AM)
Requirement
Measuring Device: Oscilloscope and Millivoltmeter
Test Point: Lch, Rch, GND
Adjustment Point: L802
(1) Adjust the setting of Standard Signal Generator (hereinafter S.S.G) to 1000 kHz of 30 % variation.
(2) Adjust the reception frequency of the set to 1000 kHz.
(3) While looking at the waveform on the oscilloscope, reduce the output level all the way.
(4) Adjust L802 until the value of the millivoltmeter reaches the maximum.
5. Tracking Adjustment (MW)
Requirement
Measuring Device: Oscilloscope and millivoltmeter
TE
L 13942296513
Test Point: Lch, Rch, GND
Adjustment Point: L951
(1) Adjust the S.S.G setting to 1000 kHz of 30 % variation.
(2) While looking at the waveform on the oscilloscope, reduce the output level all the way.
(approximately 80 dBuV).
(3) Adjust L951 until the value of the millivoltmeter reaches the maximum.
6. Auto Stop Check (MW)
Requirement
(1) Adjust the S.S.G setting to 1000 kHz, 30 % variation, and 78 dBuV ± 10 dBuV for the output level.
(2) Activate the tuner search function, and check that there is reception of 1000 kHz.
www
.
http://www.xiaoyu163.com
60cm
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
SET
TP
Lch
Rch
GND
Fig. 2
Q Q
3
6 7
1 3
1 5
co
.
– 34 –
9 4
2 8
Connect to the respective measuring device
OSCILLOSCOPE
CH1
CH2
Lch
Rch
GND
AC MILLIVOLTMETER
0 5
8
2 9
9 4
2 8
CH1
CH2
Lch
GND
GND
Rch
m
9 9
GND
9 9