2. Press the "1" or "2" key to display the present compensation level for the start position.
Compensation levels can be adjusted in 11 steps from -5 to +5 (mm).
3. Press the key to increase compensation levels, and the key to lower them.
Press the "Stop/Exit" key, and the machine returns to the initial state of the maintenance mode without
adjusting compensation levels.
4. Press the "Menu/Set" key.
The "ACCEPTED" will appear on the LCD. One second later, the machine returns to the initial stage
of the maintenance mode.
• [A]: "5" and "4" keys
• [B]: "Menu/Set" key
• [C]: "Stop/Exit" key
• The correlation between the scan start/end positions and compensation levels is shown above.
Acquisition of White Level Data and CIS Scanner Area Setting (Function code 55)
Function
This function allows the machine to obtain white level data for the CIS scanner and save it together with
the CIS scanner area into the EEPROM on the main PCB.
Detailed Description of Maintenance-Mode Functions
5
143